Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0077 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $119,680 | $350,000 | Implemented |
DL0077 # 03 Y:2011 | 03 | 2011 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $63,615 | $100,500 | Not Implemented |
DL0077 # 04 Y:2011 | 04 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $31,497 | $800 | Not Implemented |
DL0077 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $21,318 | $1,600 | Implemented |
DL0077 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $24,600 | $18,000 | Not Implemented |
DL0077 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,771 | $11,600 | Implemented |
DL0077 # 08 Y:2011 | 08 | 2011 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $5,717 | $900 | Not Implemented |
DL0077 # 01 Y:2011 | 01 | 2011 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $20,592 | $3,200 | Not Implemented |
MA0679 # 06 Y:2011 | 06 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,785 | $11,650 | Implemented |
MA0679 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,376 | $55,750 | Implemented |
MA0679 # 04 Y:2011 | 04 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,015 | $30,000 | Implemented |
MA0679 # 03 Y:2011 | 03 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $24,174 | $55,000 | Implemented |
MA0679 # 02 Y:2011 | 02 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $45,173 | $20,100 | Implemented |
MA0679 # 01 Y:2011 | 01 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $70,691 | $20,000 | Implemented |
SU0312 # 02 Y:2011 | 02 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,162 | $0 | Not Implemented |
SU0312 # 10 Y:2011 | 10 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $474 | $880 | Implemented |
SU0312 # 03 Y:2011 | 03 | 2011 | DISCONNECT BALLASTS | $1,584 | $0 | Implemented |
SU0312 # 07 Y:2011 | 07 | 2011 | REDUCE VENTILATION AIR | $13,505 | $13,112 | Implemented |
SU0312 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $308 | $450 | Not Implemented |
SU0312 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $588 | $283 | Implemented |
SU0312 # 09 Y:2011 | 09 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,778 | $12,185 | Not Implemented |
SU0312 # 12 Y:2011 | 12 | 2011 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $276 | $4,481 | Implemented |
SU0312 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,080 | $0 | Implemented |
SU0312 # 11 Y:2011 | 11 | 2011 | OPTIMIZE PLANT POWER FACTOR | $1,695 | $15,783 | Not Implemented |
SU0312 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,822 | $177 | Not Implemented |