Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
232
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0402 # 11 Y:2015 | 11 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $385 | $1,496 | Not Implemented |
SU0402 # 02 Y:2015 | 02 | 2015 | DISCONNECT BALLASTS | $375 | $0 | Not Implemented |
SU0402 # 10 Y:2015 | 10 | 2015 | UPGRADE OBSOLETE EQUIPMENT | $7,911 | $23,244 | Implemented |
SU0402 # 07 Y:2015 | 07 | 2015 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $770 | $950 | Implemented |
SU0402 # 01 Y:2015 | 01 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $851 | $0 | Not Implemented |
SU0402 # 05 Y:2015 | 05 | 2015 | REDUCE VENTILATION AIR | $8,182 | $2,941 | Implemented |
SU0402 # 08 Y:2015 | 08 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $1,495 | $2,000 | Implemented |
SU0402 # 06 Y:2015 | 06 | 2015 | ELIMINATE/REDUCE AN OPERATION | $5,835 | $2,320 | Not Implemented |
SU0402 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $431 | $560 | Implemented |
SU0402 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $1,500 | $297 | Not Implemented |
SU0402 # 03 Y:2015 | 03 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,073 | $600 | Implemented |
SU0401 # 08 Y:2015 | 08 | 2015 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $9,780 | $49,000 | Not Implemented |
SU0401 # 07 Y:2015 | 07 | 2015 | ELIMINATE/REDUCE AN OPERATION | $956 | $3,709 | Not Implemented |
SU0401 # 06 Y:2015 | 06 | 2015 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $218 | $404 | Not Implemented |
SU0401 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $383 | $240 | Implemented |
SU0401 # 02 Y:2015 | 02 | 2015 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $3,274 | $1,580 | Implemented |
SU0401 # 01 Y:2015 | 01 | 2015 | PAY BILLS ON TIME TO AVOID LATE FEES | $2,820 | $0 | Implemented |
SU0401 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $964 | $469 | Not Implemented |
SU0401 # 05 Y:2015 | 05 | 2015 | REPLACE BOILER | $11,805 | $10,686 | Implemented |
MA0752 # 07 Y:2015 | 07 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,691 | $4,785 | Not Implemented |
MA0752 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,894 | $203 | Not Implemented |
MA0752 # 05 Y:2015 | 05 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,878 | $100 | Not Implemented |
MA0752 # 04 Y:2015 | 04 | 2015 | REDUCE VENTILATION AIR | $16,956 | $9,990 | Not Implemented |
MA0752 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $37,599 | $47,900 | Implemented |
MA0752 # 02 Y:2015 | 02 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,566 | $37,930 | Implemented |