Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

117

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0322 # 01 Y:2012 01 2012 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $6,386 $0 Implemented
SU0322 # 02 Y:2012 02 2012 REDUCE VENTILATION AIR $12,242 $7,179 Not Implemented
SU0322 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $876 $528 Implemented
SU0322 # 04 Y:2012 04 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $109 $298 Not Implemented
SU0322 # 05 Y:2012 05 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $229 $639 Not Implemented
SU0322 # 06 Y:2012 06 2012 DISCONNECT BALLASTS $2,772 $9,240 Implemented
SU0322 # 07 Y:2012 07 2012 UPGRADE OBSOLETE EQUIPMENT $1,164 $5,472 Implemented
LE0339 # 01 Y:2012 01 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,689 $3,000 Not Implemented
LE0339 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,390 $13,920 Not Implemented
LE0339 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,612 $13,428 Implemented
LE0339 # 04 Y:2012 04 2012 INSTALL OCCUPANCY SENSORS $2,652 $3,590 Not Implemented
LE0339 # 05 Y:2012 05 2012 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,198 $9,800 Implemented
LE0339 # 06 Y:2012 06 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $21,354 $70,000 Not Implemented
LE0339 # 07 Y:2012 07 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,280 $1,000 Implemented
LE0339 # 08 Y:2012 08 2012 PREHEAT COMBUSTION AIR WITH WASTE HEAT $11,007 $20,000 Not Implemented
LE0339 # 09 Y:2012 09 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $28,832 $20,000 Not Implemented
LE0339 # 10 Y:2012 10 2012 REPAIR OR REPLACE STEAM TRAPS $13,433 $0 Implemented
LE0339 # 11 Y:2012 11 2012 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $59,246 $10,500 Not Implemented
SU0320 # 01 Y:2012 01 2012 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,185 $0 Not Implemented
SU0320 # 02 Y:2012 02 2012 REDUCE VENTILATION AIR $7,403 $5,019 Not Implemented
SU0320 # 03 Y:2012 03 2012 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $18,749 $42,038 Not Implemented
SU0320 # 04 Y:2012 04 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $391 $1,332 Not Implemented
SU0320 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,671 $37,046 Not Implemented
SU0320 # 06 Y:2012 06 2012 MAKE A NEW BY-PRODUCT $21,685 $100,000 Not Implemented
SU0320 # 07 Y:2012 07 2012 ELIMINATE/REDUCE AN OPERATION $2,644 $15,840 Not Implemented