IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

260

matching recommendations
Reset
SIC 27 Printing And Publishing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0584 # 01 Y:1999 01 1999 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $28,107 $3,150 Implemented
UD0584 # 02 Y:1999 02 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $998 $1,200 Implemented
UD0584 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $981 $356 Implemented
UM0107 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,746 $3,572 Not Implemented
UM0107 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $250 $250 Not Implemented
UM0107 # 03 Y:1998 03 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,179 $250 Not Implemented
UM0107 # 04 Y:1998 04 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $130 $100 Not Implemented
UM0107 # 05 Y:1998 05 1998 $10,400 $2,250 Not Implemented
UM0107 # 06 Y:1998 06 1998 $14,550 $5,200 Not Implemented
UD0526 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $14,725 $15,000 Implemented
UD0526 # 02 Y:1997 02 1997 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,197 $5,000 Implemented
UD0526 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,181 $11,751 Implemented
UD0524 # 01 Y:1997 01 1997 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $1,145 $0 Implemented
UD0524 # 02 Y:1997 02 1997 USE OPTIMUM THICKNESS INSULATION $1,914 $9,400 Implemented
UD0524 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,568 $0 Not Implemented
UD0524 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,898 $16,158 Implemented
UD0524 # 05 Y:1997 05 1997 REPLACE DC EQUIPMENT WITH AC EQUIPMENT $5,400 $22,500 Implemented
UD0503 # 01 Y:1996 01 1996 OPTIMIZE PLANT POWER FACTOR $4,355 $4,000 Implemented
UD0503 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,164 $12,748 Not Implemented
UD0503 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $-368 $10,000 Implemented
UD0503 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $449 $500 Not Implemented
UD0503 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,143 $31,020 Implemented
UD0503 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,120 $600 Implemented
UD0503 # 07 Y:1996 07 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,772 $500 Implemented
UD0503 # 08 Y:1996 08 1996 PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) $28,200 $0 Implemented