Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0315 # 05 Y:1990 | 05 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,503 | $0 | Not Implemented |
UD0315 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,852 | $2,800 | Implemented |
UD0315 # 03 Y:1990 | 03 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $33,180 | $70,000 | Implemented |
UD0315 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $50,970 | $40,000 | Implemented |
UD0315 # 01 Y:1990 | 01 | 1990 | INSTALL STORM WINDOWS AND DOORS | $12,565 | $12,000 | Implemented |
UD0313 # 04 Y:1990 | 04 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,376 | $25,000 | Implemented |
UD0313 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $240 | Not Implemented |
UD0313 # 02 Y:1990 | 02 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $706 | $700 | Implemented |
UD0313 # 01 Y:1990 | 01 | 1990 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $5,744 | $20,000 | Implemented |
UD0311 # 04 Y:1990 | 04 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,107 | $6,000 | Not Implemented |
UD0311 # 03 Y:1990 | 03 | 1990 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $549 | $0 | Implemented |
UD0311 # 02 Y:1990 | 02 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $678 | $250 | Not Implemented |
UD0311 # 01 Y:1990 | 01 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,733 | $2,400 | Implemented |
UD0310 # 06 Y:1990 | 06 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,867 | $25,000 | Not Implemented |
UD0310 # 02 Y:1990 | 02 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $862 | $0 | Implemented |
UD0310 # 03 Y:1990 | 03 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $170 | $0 | Implemented |
UD0310 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,326 | $442 | Implemented |
UD0310 # 05 Y:1990 | 05 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $907 | $1,800 | Implemented |
UD0309 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,076 | $18,000 | Not Implemented |
UD0310 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,258 | $0 | Not Implemented |
UD0309 # 06 Y:1990 | 06 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,028 | $10,000 | Implemented |
UD0309 # 05 Y:1990 | 05 | 1990 | INSTALL SET-BACK TIMERS | $900 | $500 | Not Implemented |
UD0309 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,374 | $8,000 | Not Implemented |
UD0309 # 03 Y:1990 | 03 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $1,295 | $200 | Implemented |
UD0309 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,951 | $700 | Implemented |