Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0091 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $11,682 $4,000 Not Implemented
UD0092 # 04 Y:1983 04 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,590 $1,300 Not Implemented
UD0092 # 03 Y:1983 03 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,757 $250 Not Implemented
UD0092 # 02 Y:1983 02 1983 INSTALL STORM WINDOWS AND DOORS $4,277 $8,800 Not Implemented
UD0092 # 01 Y:1983 01 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,885 $200 Not Implemented
UD0091 # 01 Y:1983 01 1983 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $13,041 $4,710 Not Implemented
UD0091 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,369 $2,467 Not Implemented
UD0091 # 04 Y:1983 04 1983 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,053 $6,225 Not Implemented
UD0091 # 05 Y:1983 05 1983 INSTALL STORM WINDOWS AND DOORS $1,186 $2,252 Not Implemented
UD0091 # 06 Y:1983 06 1983 REDESIGN PROCESS $13,696 $30,000 Implemented
UD0087 # 03 Y:1983 03 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,975 $6,000 Not Implemented
UD0087 # 02 Y:1983 02 1983 TURN OFF EQUIPMENT WHEN NOT IN USE $647 $0 Not Implemented
UD0087 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,289 $305 Not Implemented
UD0082 # 03 Y:1983 03 1983 INSULATE BARE EQUIPMENT $922 $1,200 Not Implemented
UD0082 # 04 Y:1983 04 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $4,811 $0 Not Implemented
UD0082 # 02 Y:1983 02 1983 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $170 $0 Not Implemented
UD0082 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $820 $206 Not Implemented
UD0077 # 05 Y:1983 05 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,515 $0 Not Implemented
UD0077 # 04 Y:1983 04 1983 REDUCE GLAZED AREAS IN BUILDINGS $1,268 $3,680 Not Implemented
UD0077 # 03 Y:1983 03 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,967 $500 Implemented
UD0077 # 02 Y:1983 02 1983 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,987 $2,000 Implemented
UD0077 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $963 $354 Not Implemented