IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

119

matching recommendations
Reset
SIC 3462 Iron And Steel Forgings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0617 # 07 Y:2001 07 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,073 $0 Not Implemented
UD0542 # 01 Y:1998 01 1998 $183,600 $0 Implemented
UD0542 # 02 Y:1998 02 1998 RECOVER METALS FROM CASTING SAND $21,000 $4,800 Not Implemented
UD0542 # 03 Y:1998 03 1998 USE POWER DURING OFF-PEAK PERIODS $11,143 $0 Implemented
UD0542 # 04 Y:1998 04 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $8,400 $0 Implemented
UD0542 # 05 Y:1998 05 1998 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $8,000 $17,000 Not Implemented
UD0542 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,513 $14,128 Implemented
UD0542 # 07 Y:1998 07 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,236 $20,000 Not Implemented
UD0542 # 08 Y:1998 08 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,053 $0 Not Implemented
UD0218 # 01 Y:1987 01 1987 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $19,049 $5,470 Implemented
UD0218 # 02 Y:1987 02 1987 RECOVER WASTE HEAT FROM EQUIPMENT $3,039 $9,500 Not Implemented
UD0218 # 03 Y:1987 03 1987 TURN OFF EQUIPMENT WHEN NOT IN USE $463 $129 Not Implemented
UD0218 # 04 Y:1987 04 1987 USE DEMAND CONTROLLER OR LOAD SHEDDER $11,481 $0 Implemented
UD0056 # 01 Y:1982 01 1982 INSTALL STORM WINDOWS AND DOORS $773 $600 Not Implemented
UD0056 # 02 Y:1982 02 1982 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $232,119 $517,000 Not Implemented
UD0056 # 03 Y:1982 03 1982 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $13,145 $517,000 Not Implemented
UD0052 # 01 Y:1982 01 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,538 $900 Not Implemented
UD0052 # 02 Y:1982 02 1982 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $182,775 $87,000 Not Implemented
UD0052 # 03 Y:1982 03 1982 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $27,811 $0 Not Implemented