Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

155

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0951 # 01 Y:2016 01 2016 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,773 $0 Not Implemented
UD0951 # 03 Y:2016 03 2016 CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS $5,257 $700 Not Implemented
UD0908 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,160 $1,000 Implemented
UD0908 # 09 Y:2014 09 2014 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,140 $0 Implemented
UD0908 # 07 Y:2014 07 2014 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $32,358 $66,625 Not Implemented
UD0908 # 01 Y:2014 01 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $561 $0 Not Implemented
UD0908 # 12 Y:2014 12 2014 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,340 $3,000 Implemented
UD0908 # 10 Y:2014 10 2014 REUSE / RECYCLE/ SELL PAPER PRODUCTS $4,376 $500 Implemented
UD0908 # 06 Y:2014 06 2014 ADD AREA LIGHTING SWITCHES $4,592 $0 Implemented
UD0908 # 08 Y:2014 08 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,910 $0 Implemented
UD0908 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,164 $55,583 Not Implemented
UD0908 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,198 $1,000 Implemented
UD0908 # 11 Y:2014 11 2014 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,363 $0 Implemented
UD0908 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,576 $0 Not Implemented
UD0870 # 02 Y:2012 02 2012 UPGRADE CONTROLS ON COMPRESSORS $5,228 $10,000 Implemented
UD0870 # 11 Y:2012 11 2012 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,788 $3,000 Implemented
UD0870 # 09 Y:2012 09 2012 ISOLATE HOT OR COLD EQUIPMENT $1,602 $4,000 Not Implemented
UD0870 # 10 Y:2012 10 2012 INSULATE BARE EQUIPMENT $1,512 $0 Implemented
UD0870 # 08 Y:2012 08 2012 RECOVER WASTE HEAT FROM EQUIPMENT $2,567 $4,000 Not Implemented
UD0870 # 07 Y:2012 07 2012 USE MINIMUM STEAM OPERATING PRESSURE $7,517 $0 Implemented
UD0870 # 05 Y:2012 05 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,199 $1,500 Implemented
UD0870 # 06 Y:2012 06 2012 REPAIR OR REPLACE STEAM TRAPS $10,454 $1,800 Implemented
UD0870 # 04 Y:2012 04 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,610 $1,500 Implemented
UD0870 # 03 Y:2012 03 2012 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,564 $16,800 Not Implemented
UD0870 # 01 Y:2012 01 2012 USE PHOTOCELL CONTROLS $1,385 $1,660 Implemented