Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,072
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0731 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $9,619 | $520 | Not Implemented |
UD0731 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,198 | $0 | Not Implemented |
UD0731 # 14 Y:2005 | 14 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,010 | $0 | Implemented |
UD0731 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $54,200 | $60,000 | Implemented |
UD0731 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,953 | $15,113 | Implemented |
UD0731 # 07 Y:2005 | 07 | 2005 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $12,378 | $0 | Implemented |
UD0731 # 05 Y:2005 | 05 | 2005 | CONDENSE OPERATION INTO ONE BUILDING | $13,200 | $0 | Not Implemented |
UD0731 # 03 Y:2005 | 03 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $24,427 | $0 | Not Implemented |
UD0731 # 15 Y:2005 | 15 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $622 | $0 | Implemented |
UD0731 # 09 Y:2005 | 09 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,841 | $0 | Implemented |
UD0731 # 12 Y:2005 | 12 | 2005 | REDUCE VENTILATION AIR | $1,932 | $119 | Not Implemented |
UD0731 # 11 Y:2005 | 11 | 2005 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $4,182 | $0 | Not Implemented |
UD0731 # 16 Y:2005 | 16 | 2005 | DISCONNECT BALLASTS | $440 | $66 | Not Implemented |
UD0731 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,130 | $0 | Not Implemented |
UD0731 # 02 Y:2005 | 02 | 2005 | CONDENSE OPERATION INTO ONE BUILDING | $28,800 | $0 | Not Implemented |
UD0731 # 13 Y:2005 | 13 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,894 | $0 | Implemented |
UD0730 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,473 | $12,880 | Implemented |
UD0730 # 10 Y:2005 | 10 | 2005 | USE MINIMUM SAFE OVEN VENTILATION | $3,222 | $150 | Not Implemented |
UD0730 # 01 Y:2005 | 01 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $40,357 | $3,600 | Not Implemented |
UD0730 # 11 Y:2005 | 11 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,840 | $945 | Implemented |
UD0730 # 14 Y:2005 | 14 | 2005 | INSTALL OCCUPANCY SENSORS | $192 | $600 | Not Implemented |
UD0730 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,232 | $9,916 | Implemented |
UD0730 # 03 Y:2005 | 03 | 2005 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $13,381 | $25,000 | Not Implemented |
UD0730 # 09 Y:2005 | 09 | 2005 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $3,480 | $1,500 | Not Implemented |
UD0730 # 04 Y:2005 | 04 | 2005 | COVER OPEN TANKS | $12,069 | $2,170 | Not Implemented |