Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

178

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0418 # 06 Y:1993 06 1993 RECOVER AND REUSE COOLING WATER $12,300 $1,000 Implemented
UD0418 # 03 Y:1993 03 1993 INSTALL EFFICIENT RECTIFIERS $1,456 $15,000 Implemented
UD0417 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $191 $937 Not Implemented
UD0417 # 03 Y:1993 03 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $57,131 $250 Not Implemented
UD0417 # 01 Y:1993 01 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,791 $0 Not Implemented
UD0416 # 04 Y:1993 04 1993 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $9,061 $3,000 Implemented
UD0416 # 05 Y:1993 05 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $2,209 $0 Not Implemented
UD0416 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,163 $2,170 Implemented
UD0416 # 02 Y:1993 02 1993 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $17,440 $20,000 Not Implemented
UD0416 # 01 Y:1993 01 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,440 $0 Not Implemented
UD0415 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,263 $5,400 Not Implemented
UD0415 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,314 $31,350 Implemented
UD0415 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,514 $3,200 Not Implemented
UD0415 # 01 Y:1993 01 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,569 $0 Not Implemented
UD0415 # 02 Y:1993 02 1993 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $8,020 $3,000 Implemented
UD0415 # 03 Y:1993 03 1993 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $200,000 $480,000 Not Implemented
UD0414 # 05 Y:1993 05 1993 INSTALL SET-BACK TIMERS $1,689 $1,500 Implemented
UD0414 # 06 Y:1993 06 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,519 $0 Not Implemented
UD0414 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,246 $14,248 Implemented
UD0414 # 04 Y:1993 04 1993 INSTALL SET-BACK TIMERS $1,773 $500 Implemented
UD0414 # 02 Y:1993 02 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $20,700 $20,000 Not Implemented
UD0414 # 01 Y:1993 01 1993 PAY UTILITY BILLS ON TIME $2,100 $0 Implemented
ND0173 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $220 $280 Implemented
ND0173 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,420 $1,000 Implemented
ND0173 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,980 $7,920 Implemented