Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

70

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0604 # 04 Y:2000 04 2000 $18,577 $1,801 Implemented
OK0604 # 03 Y:2000 03 2000 $24,537 $26,122 Not Implemented
OK0604 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,442 $1,900 Not Implemented
OK0604 # 01 Y:2000 01 2000 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $7,686 $4,275 Implemented
OK0604 # 05 Y:2000 05 2000 $70,200 $47,500 Implemented
OK0439 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,568 $4,848 Not Implemented
OK0439 # 07 Y:1994 07 1994 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $1,266 $3,750 Not Implemented
OK0439 # 06 Y:1994 06 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $766 $0 Implemented
OK0439 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,114 $800 Not Implemented
OK0439 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $665 $851 Not Implemented
OK0439 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $187 $200 Implemented
OK0439 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,701 $12,214 Implemented
OK0414 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,446 $0 Implemented
OK0414 # 04 Y:1993 04 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,058 $3,889 Implemented
OK0414 # 02 Y:1993 02 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,531 $200 Implemented
OK0414 # 01 Y:1993 01 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $17,978 $19,647 Not Implemented
OK0344 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $370 $215 Implemented
OK0344 # 02 Y:1991 02 1991 RECOVER WASTE HEAT FROM EQUIPMENT $2,697 $3,038 Implemented
OK0344 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $797 $0 Implemented
OK0344 # 04 Y:1991 04 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $892 $110 Implemented
OK0344 # 05 Y:1991 05 1991 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,342 $9,572 Implemented
OK0344 # 06 Y:1991 06 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $371 $0 Implemented
OK0203 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $418 $41 Implemented
OK0203 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $273 $60 Implemented
OK0203 # 04 Y:1986 04 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $40 $55 Implemented