Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

121

matching recommendations
Reset
SIC 3531 Construction Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0624 # 02 Y:2001 02 2001 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,484 $255 Implemented
OK0624 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,627 $240 Implemented
OK0624 # 04 Y:2001 04 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,170 $50,000 Not Implemented
OK0624 # 05 Y:2001 05 2001 $131,000 $92,000 Implemented
OK0624 # 06 Y:2001 06 2001 $200,000 $200,000 Not Implemented
OK0573 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,582 $16,945 Not Implemented
OK0573 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,215 $45,737 Not Implemented
OK0573 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,266 $1,900 Implemented
OK0573 # 04 Y:1999 04 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $545 $246 Not Implemented
OK0573 # 05 Y:1999 05 1999 RECOVER AND REUSE WASTE MATERIAL $13,831 $8,000 Not Implemented
OK0573 # 06 Y:1999 06 1999 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,895 $34,750 Implemented
OK0565 # 01 Y:1999 01 1999 INSTALL SET-BACK TIMERS $24,864 $2,525 Not Implemented
OK0565 # 02 Y:1999 02 1999 INSTALL OCCUPANCY SENSORS $962 $1,510 Not Implemented
OK0565 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,696 $15,450 Implemented
OK0565 # 04 Y:1999 04 1999 $49,521 $3,600 Implemented
OK0565 # 05 Y:1999 05 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $4,706 $0 Not Implemented
OK0565 # 06 Y:1999 06 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $8,319 $0 Not Implemented
OK0565 # 07 Y:1999 07 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $3,120 $0 Not Implemented
OK0534 # 01 Y:1997 01 1997 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $285,720 $575,000 Implemented
OK0534 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $128,530 $202,500 Implemented
OK0534 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,249 $124,654 Implemented
OK0534 # 04 Y:1997 04 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $9,484 $18,600 Implemented
OK0534 # 05 Y:1997 05 1997 $6,240 $268,000 Not Implemented
OK0534 # 06 Y:1997 06 1997 USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) $5,542 $27,375 Implemented
OK0534 # 07 Y:1997 07 1997 USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) $5,196 $1,000 Implemented