IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

115

matching recommendations
Reset
SIC 3714 Motor Vehicle Parts And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0591 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,477 $4,942 Implemented
OK0591 # 03 Y:2000 03 2000 INSTALL OCCUPANCY SENSORS $875 $136 Not Implemented
OK0591 # 04 Y:2000 04 2000 BURN A LESS EXPENSIVE GRADE OF FUEL $9,042 $230,000 Not Implemented
OK0591 # 05 Y:2000 05 2000 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $181,048 $59,400 Not Implemented
OK0591 # 06 Y:2000 06 2000 $21,407 $30,000 Not Implemented
OK0486 # 01 Y:1996 01 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,955 $5,951 Not Implemented
OK0486 # 02 Y:1996 02 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,401 $3,275 Implemented
OK0486 # 03 Y:1996 03 1996 IMPROVE LUBRICATION PRACTICES $4,213 $0 Not Implemented
OK0486 # 04 Y:1996 04 1996 UPGRADE CONTROLS ON COMPRESSORS $1,548 $5,600 Implemented
OK0486 # 05 Y:1996 05 1996 DISCONNECT BALLASTS $428 $1,060 Implemented
OK0486 # 06 Y:1996 06 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $203 $757 Implemented
OK0486 # 07 Y:1996 07 1996 TREAT AND REUSE RINSE WATERS $17,249 $0 Not Implemented
OK0429 # 01 Y:1994 01 1994 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $1,839 $2,500 Implemented
OK0429 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,730 $1,600 Implemented
OK0429 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,310 $0 Implemented
OK0429 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $638 $0 Implemented
OK0429 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $711 $2,806 Not Implemented
OK0409 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,933 $15,898 Implemented
OK0409 # 02 Y:1993 02 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $584 $0 Implemented
OK0409 # 03 Y:1993 03 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $560 $0 Not Implemented
OK0409 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $366 $0 Implemented
OK0409 # 05 Y:1993 05 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $123 $0 Not Implemented
OK0409 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $102 $304 Implemented
OK0337 # 01 Y:1991 01 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $59,130 $29,025 Implemented
OK0337 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $24,414 $1,184 Implemented