Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0668 # 10 Y:2003 | 10 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,501 | $6,296 | Not Implemented |
OK0668 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $1,369 | $1,455 | Implemented |
OK0668 # 08 Y:2003 | 08 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,772 | $9,500 | Not Implemented |
OK0668 # 07 Y:2003 | 07 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $50,260 | $51,780 | Not Implemented |
OK0668 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $21,821 | $1,125 | Implemented |
OK0668 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $67,238 | $0 | Implemented |
OK0668 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,597 | $0 | Implemented |
OK0668 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $6,113 | $1,885 | Implemented |
OK0668 # 13 Y:2003 | 13 | 2003 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $38,034 | $1,647 | Implemented |
OK0668 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,013 | $38,456 | Implemented |
OK0668 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,150 | $61,955 | Not Implemented |
OK0668 # 11 Y:2003 | 11 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,447 | $112,608 | n/a |
OK0668 # 12 Y:2003 | 12 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,404 | $34,425 | n/a |
OK0665 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,602 | $0 | Not Implemented |
OK0665 # 09 Y:2003 | 09 | 2003 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $7,136 | $32,000 | n/a |
OK0665 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,270 | $1,048 | Implemented |
OK0665 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,550 | $13,880 | Implemented |
OK0665 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $1,398 | $1,374 | Not Implemented |
OK0665 # 05 Y:2003 | 05 | 2003 | $10,600 | $0 | Implemented | |
OK0665 # 04 Y:2003 | 04 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,748 | $3,480 | Implemented |
OK0665 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,094 | $6,844 | Not Implemented |
OK0665 # 01 Y:2003 | 01 | 2003 | INSTALL SET-BACK TIMERS | $4,895 | $664 | Implemented |
OK0654 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $336 | $349 | Not Implemented |
OK0654 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $640 | Not Implemented |
OK0654 # 03 Y:2003 | 03 | 2003 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,131 | $0 | Not Implemented |