Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
258
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0151 # 05 Y:1984 | 05 | 1984 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $984 | $0 | Not Implemented |
OK0151 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $4,492 | $1,100 | Implemented |
OK0152 # 08 Y:1984 | 08 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $58 | $58 | Implemented |
OK0152 # 07 Y:1984 | 07 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $117 | $124 | Implemented |
OK0151 # 04 Y:1984 | 04 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $334 | $0 | Implemented |
OK0151 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58 | $48 | Implemented |
OK0152 # 05 Y:1984 | 05 | 1984 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $204 | $0 | Implemented |
OK0152 # 03 Y:1984 | 03 | 1984 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $292 | $480 | Implemented |
OK0152 # 02 Y:1984 | 02 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $196 | $530 | Implemented |
OK0152 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $146 | $250 | Not Implemented |
OK0152 # 06 Y:1984 | 06 | 1984 | INSTALL SET-BACK TIMERS | $409 | $0 | Not Implemented |
OK0152 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $292 | $134 | Implemented |
OK0151 # 03 Y:1984 | 03 | 1984 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $141 | $336 | Implemented |
OK0149 # 07 Y:1984 | 07 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $126 | $235 | Implemented |
OK0150 # 05 Y:1984 | 05 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $745 | $122 | Not Implemented |
OK0150 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45 | $60 | Implemented |
OK0149 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,556 | $785 | Implemented |
OK0149 # 02 Y:1984 | 02 | 1984 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,221 | $2,000 | Not Implemented |
OK0149 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $363 | $650 | Implemented |
OK0149 # 08 Y:1984 | 08 | 1984 | INSULATE BARE EQUIPMENT | $155 | $235 | Implemented |
OK0149 # 03 Y:1984 | 03 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $351 | $220 | Implemented |
OK0149 # 09 Y:1984 | 09 | 1984 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $826 | $0 | Implemented |
OK0150 # 02 Y:1984 | 02 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $140 | $0 | Implemented |
OK0150 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $320 | $450 | Not Implemented |
OK0149 # 10 Y:1984 | 10 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,537 | $480 | Implemented |