Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
61
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0493 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,900 | $1,900 | Not Implemented |
OR0493 # 01 Y:2005 | 01 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $66,200 | $1,000 | Not Implemented |
OR0493 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $2,500 | Not Implemented |
OR0493 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,500 | $0 | Not Implemented |
OR0493 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,900 | $17,000 | Not Implemented |
OR0493 # 03 Y:2005 | 03 | 2005 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $5,400 | $1,000 | Not Implemented |
OR0493 # 04 Y:2005 | 04 | 2005 | USE OPTIMUM TEMPERATURE | $11,000 | $13,000 | Not Implemented |
OR0493 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,400 | $3,600 | Not Implemented |
OR0489 # 10 Y:2005 | 10 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $5,800 | $12,000 | Implemented |
OR0489 # 11 Y:2005 | 11 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $8,500 | $22,000 | Not Implemented |
OR0489 # 09 Y:2005 | 09 | 2005 | OPTIMIZE PLANT POWER FACTOR | $2,090 | $5,200 | Not Implemented |
OR0489 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $1,450 | $3,590 | Implemented |
OR0489 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $1,800 | $2,100 | Implemented |
OR0489 # 06 Y:2005 | 06 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,100 | $15,400 | Not Implemented |
OR0489 # 05 Y:2005 | 05 | 2005 | ADJUST VENTS TO MINIMIZE ENERGY USE | $24,900 | $12 | Implemented |
OR0489 # 03 Y:2005 | 03 | 2005 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $80,000 | $58,000 | Not Implemented |
OR0489 # 02 Y:2005 | 02 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,600 | $340 | Implemented |
OR0489 # 01 Y:2005 | 01 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $19,500 | $5,400 | Not Implemented |
OR0489 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $2,330 | $100 | Implemented |
OR0488 # 03 Y:2005 | 03 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $28,100 | $132,000 | Implemented |
OR0488 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $680 | $2,000 | Not Implemented |
OR0488 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $600 | $200 | Implemented |
OR0486 # 12 Y:2005 | 12 | 2005 | INSULATE FEEDWATER TANK | $1,800 | $1,500 | Implemented |
OR0486 # 11 Y:2005 | 11 | 2005 | USE PHOTOCELL CONTROLS | $2,700 | $1,300 | Implemented |
OR0486 # 09 Y:2005 | 09 | 2005 | OPTIMIZE PLANT POWER FACTOR | $3,350 | $3,050 | Implemented |