Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
72
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0345 # 08 Y:2018 | 08 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $785 | $1,560 | Not Implemented |
MI0345 # 07 Y:2018 | 07 | 2018 | OPTIMIZE PLANT POWER FACTOR | $810 | $2,138 | Not Implemented |
MI0345 # 06 Y:2018 | 06 | 2018 | USE SOLAR HEAT TO HEAT WATER | $1,166 | $2,755 | Implemented |
MI0345 # 05 Y:2018 | 05 | 2018 | INSTALL OCCUPANCY SENSORS | $1,380 | $540 | Implemented |
MI0345 # 04 Y:2018 | 04 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,410 | $1,982 | Not Implemented |
MI0345 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,576 | $3,443 | Implemented |
MI0345 # 02 Y:2018 | 02 | 2018 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $6,837 | $3,204 | Implemented |
MI0345 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,969 | $3,100 | Implemented |
MI0344 # 06 Y:2018 | 06 | 2018 | USE PHOTOCELL CONTROLS | $3,042 | $2,219 | Implemented |
MI0344 # 01 Y:2018 | 01 | 2018 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $55,478 | $62,800 | Not Implemented |
MI0344 # 02 Y:2018 | 02 | 2018 | OPTIMIZE PLANT POWER FACTOR | $12,638 | $18,415 | Not Implemented |
MI0344 # 03 Y:2018 | 03 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,405 | $6,666 | Implemented |
MI0344 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,313 | $15,147 | Implemented |
MI0344 # 05 Y:2018 | 05 | 2018 | INSULATE BARE EQUIPMENT | $7,317 | $9,570 | Not Implemented |
MI0344 # 07 Y:2018 | 07 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,495 | $2,030 | Implemented |
MI0344 # 08 Y:2018 | 08 | 2018 | INSTALL OCCUPANCY SENSORS | $1,536 | $846 | Implemented |
MI0344 # 09 Y:2018 | 09 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $474 | $760 | Implemented |
MI0342 # 07 Y:2018 | 07 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $770 | $80 | Implemented |
MI0342 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $56,921 | $3,280 | Implemented |
MI0342 # 02 Y:2018 | 02 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $48,793 | $800 | Implemented |
MI0342 # 03 Y:2018 | 03 | 2018 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $32,500 | $15,000 | Implemented |
MI0342 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,885 | $4,165 | Implemented |
MI0342 # 04 Y:2018 | 04 | 2018 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $15,291 | $14,298 | Implemented |
MI0342 # 06 Y:2018 | 06 | 2018 | OPTIMIZE PLANT POWER FACTOR | $3,475 | $14,430 | Not Implemented |
MI0341 # 02 Y:2018 | 02 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $75,087 | $115,295 | Not Implemented |