Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
172
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0534 # 12 Y:1994 | 12 | 1994 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $19,372 | $10,640 | Not Implemented |
TN0534 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $482 | $367 | Implemented |
TN0534 # 05 Y:1994 | 05 | 1994 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $537 | $0 | Implemented |
TN0534 # 04 Y:1994 | 04 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $854 | $0 | Not Implemented |
TN0534 # 02 Y:1994 | 02 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $2,466 | $1,200 | Not Implemented |
TN0534 # 09 Y:1994 | 09 | 1994 | INSULATE BARE EQUIPMENT | $179 | $220 | Implemented |
TN0534 # 08 Y:1994 | 08 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $262 | $240 | Not Implemented |
TN0534 # 11 Y:1994 | 11 | 1994 | USE LESS WASTEFUL PACKAGING | $21,100 | $34,000 | Not Implemented |
TN0534 # 13 Y:1994 | 13 | 1994 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,956 | $13,600 | Not Implemented |
TN0534 # 10 Y:1994 | 10 | 1994 | REDUCE SCRAP PRODUCTION | $45,069 | $91,600 | Not Implemented |
TN0534 # 03 Y:1994 | 03 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,161 | $0 | Implemented |
TN0534 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,495 | $9,920 | Implemented |
TN0534 # 07 Y:1994 | 07 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $427 | $860 | Implemented |
TN0521 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $271 | $204 | Implemented |
TN0521 # 03 Y:1994 | 03 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,054 | $9,625 | Not Implemented |
TN0521 # 02 Y:1994 | 02 | 1994 | REPAIR OR REPLACE STEAM TRAPS | $5,579 | $725 | Not Implemented |
TN0521 # 01 Y:1994 | 01 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,374 | $3,540 | Not Implemented |
TN0521 # 05 Y:1994 | 05 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,290 | $0 | Implemented |
TN0521 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,353 | $195 | Implemented |
TN0536 # 02 Y:1994 | 02 | 1994 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,818 | $2,816 | Not Implemented |
TN0536 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,869 | $980 | Implemented |
TN0536 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,717 | $0 | Implemented |
TN0536 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,161 | $2,055 | Implemented |
TN0536 # 11 Y:1994 | 11 | 1994 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,944 | $8,480 | Implemented |
TN0536 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,311 | $0 | Implemented |