Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0467 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,208 | $1,180 | Implemented |
NC0467 # 03 Y:2012 | 03 | 2012 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,485 | $18,400 | Not Implemented |
NC0467 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $290 | $1,265 | Not Implemented |
NC0467 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $146 | $652 | Implemented |
NC0467 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $448 | $525 | Implemented |
NC0467 # 06 Y:2012 | 06 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $347 | $1,200 | Not Implemented |
NC0467 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $245 | $100 | Implemented |
NC0467 # 09 Y:2012 | 09 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $34,729 | $15,000 | Implemented |
NC0467 # 08 Y:2012 | 08 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $459 | $300 | Implemented |
NC0468 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,060 | $800 | Implemented |
NC0468 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $464 | $2,021 | Not Implemented |
NC0468 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $785 | $900 | Not Implemented |
NC0468 # 04 Y:2012 | 04 | 2012 | INSTALL COMMON HEADER ON COMPRESSORS | $16,574 | $8,026 | Not Implemented |
NC0468 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,026 | $18,000 | Implemented |
NC0468 # 09 Y:2012 | 09 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,973 | $2,136 | Not Implemented |
NC0468 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $867 | $1,668 | Not Implemented |
NC0468 # 11 Y:2012 | 11 | 2012 | INSTALL OCCUPANCY SENSORS | $2,082 | $2,100 | Implemented |
NC0468 # 12 Y:2012 | 12 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $34,749 | $7,000 | Implemented |
NC0468 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $715 | Not Implemented |
NC0468 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $128 | $301 | Not Implemented |
NC0468 # 10 Y:2012 | 10 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,293 | $4,125 | Not Implemented |
WV0452 # 01 Y:2012 | 01 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $50,506 | $36,000 | Not Implemented |
WV0452 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,485 | $98,452 | Not Implemented |
WV0452 # 03 Y:2012 | 03 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $21,578 | $4,825 | Implemented |
WV0452 # 04 Y:2012 | 04 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,198 | $8,840 | Not Implemented |