Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

165

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0645 # 01 Y:1998 01 1998 ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT $408,630 $24,685 Implemented
TN0645 # 12 Y:1998 12 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,310 $1,120 Not Implemented
TN0645 # 08 Y:1998 08 1998 TREAT AND REUSE RINSE WATERS $28,105 $69,200 Not Implemented
TN0645 # 07 Y:1998 07 1998 USE DEIONIZED WATER IN UPSTREAM RINSE TANKS $48,650 $120,000 Not Implemented
TN0645 # 06 Y:1998 06 1998 USE A DIFFERENT OR RECYCLED RAW MATERIAL $51,945 $200,000 Not Implemented
TN0645 # 02 Y:1998 02 1998 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $277,345 $644,800 Not Implemented
TN0645 # 03 Y:1998 03 1998 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $237,600 $153,485 Not Implemented
TN0645 # 04 Y:1998 04 1998 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $221,455 $70,000 Not Implemented
TN0645 # 05 Y:1998 05 1998 $198,225 $250,000 Not Implemented
OD0123 # 02 Y:1998 02 1998 INSTALL OCCUPANCY SENSORS $609 $200 Not Implemented
OD0123 # 01 Y:1998 01 1998 USE OPTIMUM THICKNESS INSULATION $7,666 $21,040 Not Implemented
OD0123 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,239 $16,477 Not Implemented
OD0123 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $592 $1,290 Not Implemented
OD0122 # 02 Y:1998 02 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,277 $150 Not Implemented
OD0122 # 06 Y:1998 06 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,871 $1,050 Implemented
OD0122 # 04 Y:1998 04 1998 SHUT OFF PILOTS IN STANDBY EQUIPMENT $248 $20 Not Implemented
OD0122 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,564 $3,171 Not Implemented
OD0122 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $932 $200 Not Implemented
OD0122 # 05 Y:1998 05 1998 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,545 $93 Implemented
OD0121 # 06 Y:1998 06 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,833 $1,495 Implemented
OD0121 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,192 $6,908 Implemented
OD0121 # 05 Y:1998 05 1998 REPAIR OR REPLACE STEAM TRAPS $672 $110 Implemented
OD0121 # 02 Y:1998 02 1998 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $3,843 $9,910 Not Implemented
OD0121 # 04 Y:1998 04 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $365 $220 Implemented
OD0121 # 07 Y:1998 07 1998 INSTALL STEAM TRAP $1,445 $560 Not Implemented