Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
48
matching recommendationsSIC | 49 | Electric, Gas, And Sanitary Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0627 # 10 Y:2014 | 10 | 2014 | USE PHOTOCELL CONTROLS | $3,741 | $7,191 | Implemented |
OR0627 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,856 | $39,597 | Implemented |
OR0606 # 01 Y:2013 | 01 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $161,379 | $344 | Not Implemented |
OR0606 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $39,128 | $0 | Not Implemented |
OR0606 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $119,795 | $0 | Not Implemented |
OR0606 # 04 Y:2013 | 04 | 2013 | CHANGE OPERATING CONDITIONS | $14,380 | $0 | Not Implemented |
OR0606 # 05 Y:2013 | 05 | 2013 | REDUCE FLUID FLOW RATES | $9,051 | $9,200 | Not Implemented |
OR0606 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20,282 | $25,500 | Not Implemented |
OR0605 # 03 Y:2013 | 03 | 2013 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $23,767 | $234,289 | Not Implemented |
OR0605 # 01 Y:2013 | 01 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $14,401 | $11,850 | Not Implemented |
OR0605 # 02 Y:2013 | 02 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $29,593 | $32,655 | Implemented |
OR0595 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,290 | $9,500 | Not Implemented |
OR0595 # 05 Y:2012 | 05 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,312 | $4,888 | Implemented |
OR0595 # 03 Y:2012 | 03 | 2012 | RECOVER MECHANICAL ENERGY | $1,034 | $780 | Implemented |
OR0595 # 02 Y:2012 | 02 | 2012 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $39,919 | $200,000 | Not Implemented |
OR0595 # 01 Y:2012 | 01 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $13,800 | $8,370 | Implemented |
OR0579 # 01 Y:2012 | 01 | 2012 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $15,066 | $0 | Implemented |
OR0579 # 07 Y:2012 | 07 | 2012 | USE PHOTOCELL CONTROLS | $17,340 | $46,680 | Implemented |
OR0579 # 06 Y:2012 | 06 | 2012 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $8,805 | $18,596 | Not Implemented |
OR0579 # 05 Y:2012 | 05 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,281 | $12,000 | Not Implemented |
OR0579 # 04 Y:2012 | 04 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,300 | $8,200 | Not Implemented |
OR0579 # 03 Y:2012 | 03 | 2012 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $23,346 | $55,000 | Implemented |
OR0579 # 02 Y:2012 | 02 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $125,819 | $198,800 | Not Implemented |