IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

68

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0282 # 04 Y:1996 04 1996 UPGRADE CONTROLS ON COMPRESSORS $280 $300 Implemented
OR0282 # 02 Y:1996 02 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $240 $0 Implemented
OR0282 # 03 Y:1996 03 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,164 $9,160 Not Implemented
OR0282 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $212 $664 Implemented
OR0281 # 08 Y:1996 08 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $120 $0 Implemented
OR0281 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $16,450 $34,810 Implemented
OR0281 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,510 $11,180 Implemented
OR0281 # 07 Y:1996 07 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $10,430 $50,000 Implemented
OR0281 # 01 Y:1996 01 1996 KEEP BOILER TUBES CLEAN $10,640 $800 Implemented
OR0281 # 05 Y:1996 05 1996 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $7,790 $2,000 Not Implemented
OR0281 # 06 Y:1996 06 1996 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $2,770 $5,000 Not Implemented
OR0281 # 02 Y:1996 02 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $18,000 $128,480 Implemented
OR0279 # 04 Y:1996 04 1996 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $272 $242 Not Implemented
OR0278 # 05 Y:1996 05 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,797 $7,440 Not Implemented
OR0278 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,832 $11,104 Implemented
OR0279 # 05 Y:1996 05 1996 KEEP BOILER TUBES CLEAN $1,349 $1,500 Implemented
OR0279 # 01 Y:1996 01 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,604 $0 Implemented
OR0279 # 06 Y:1996 06 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $264 $738 Not Implemented
OR0278 # 03 Y:1996 03 1996 UPGRADE CONTROLS ON COMPRESSORS $8,541 $2,640 Implemented
OR0278 # 02 Y:1996 02 1996 RECOVER WASTE HEAT FROM EQUIPMENT $6,734 $1,778 Implemented
OR0278 # 01 Y:1996 01 1996 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,492 $0 Implemented
OR0278 # 06 Y:1996 06 1996 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $10,813 $70,548 Not Implemented
OR0279 # 02 Y:1996 02 1996 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $661 $0 Not Implemented
OR0279 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN WATER LINES AND VALVES $4,754 $750 Implemented
OR0277 # 02 Y:1996 02 1996 USE OTHER WASTE CONCENTRATION METHODS $5,324 $10,000 Implemented