Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0358 # 04 Y:2007 | 04 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $24,675 | $15,300 | Implemented |
WV0358 # 03 Y:2007 | 03 | 2007 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $20,287 | $6,050 | Implemented |
WV0358 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,775 | $8,600 | Implemented |
WV0358 # 07 Y:2007 | 07 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,651 | $1,000 | Implemented |
WV0358 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,029 | $0 | Implemented |
WV0358 # 10 Y:2007 | 10 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $998 | $1,555 | Implemented |
WV0358 # 11 Y:2007 | 11 | 2007 | INSTALL OCCUPANCY SENSORS | $679 | $2,103 | Implemented |
WV0358 # 12 Y:2007 | 12 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $468 | $78 | Implemented |
WV0358 # 09 Y:2007 | 09 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $1,016 | $555 | Implemented |
WV0332 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,100 | $8,245 | Implemented |
WV0332 # 06 Y:2006 | 06 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,921 | $0 | Implemented |
WV0332 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,028 | $0 | Implemented |
WV0332 # 04 Y:2006 | 04 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $4,584 | $765 | Implemented |
WV0332 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $26,457 | $2,863 | Implemented |
WV0192 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $631 | $475 | Implemented |
WV0192 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $922 | $40 | Implemented |
WV0192 # 03 Y:2000 | 03 | 2000 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,441 | $800 | Implemented |
WV0192 # 04 Y:2000 | 04 | 2000 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $414 | $65 | Implemented |
WV0192 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,440 | $20 | Implemented |
WV0192 # 11 Y:2000 | 11 | 2000 | PAY UTILITY BILLS ON TIME | $482 | $0 | Implemented |
WV0058 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,906 | $1,304 | Implemented |
WV0058 # 06 Y:1995 | 06 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,153 | $1,075 | Implemented |
WV0058 # 05 Y:1995 | 05 | 1995 | USE SYNTHETIC LUBRICANT | $611 | $0 | Implemented |
WV0058 # 03 Y:1995 | 03 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,906 | $9,000 | Implemented |
WV0058 # 02 Y:1995 | 02 | 1995 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $2,841 | $0 | Implemented |