IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

172

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0195 # 09 Y:2000 09 2000 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,880 $100 Implemented
WV0195 # 10 Y:2000 10 2000 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $2,000 $400 Implemented
WV0195 # 06 Y:2000 06 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $531 $154 Not Implemented
WV0194 # 12 Y:2000 12 2000 $15,000 $5,824 Implemented
WV0194 # 11 Y:2000 11 2000 $22,500 $500 Not Implemented
WV0194 # 10 Y:2000 10 2000 $271,680 $200,000 Not Implemented
WV0194 # 09 Y:2000 09 2000 RECYCLE CASTING SAND $238,316 $160,000 Not Implemented
WV0194 # 08 Y:2000 08 2000 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $4,605 $5,330 Implemented
WV0194 # 07 Y:2000 07 2000 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $2,231 $1,280 Implemented
WV0194 # 06 Y:2000 06 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $318 $500 Not Implemented
WV0194 # 05 Y:2000 05 2000 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $2,224 $460 Implemented
WV0194 # 04 Y:2000 04 2000 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $1,330 $210 Implemented
WV0194 # 03 Y:2000 03 2000 USE OPTIMUM TEMPERATURE $60,864 $75,000 Not Implemented
WV0194 # 02 Y:2000 02 2000 USE RADIANT HEATER FOR SPOT HEATING $25,513 $23,400 Not Implemented
WV0194 # 01 Y:2000 01 2000 RECOVER WASTE HEAT FROM EQUIPMENT $2,827 $1,400 Not Implemented
WV0193 # 12 Y:2000 12 2000 METER WASTE WATER $79,068 $1,000 Implemented
WV0193 # 01 Y:2000 01 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $143 $164 Not Implemented
WV0193 # 02 Y:2000 02 2000 RECOVER WASTE HEAT FROM EQUIPMENT $402 $160 Not Implemented
WV0193 # 03 Y:2000 03 2000 INSTALL SPECTRAL REFLECTORS / DELAMP $1,378 $3,564 Not Implemented
WV0193 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $493 $667 Implemented
WV0193 # 05 Y:2000 05 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $373 $190 Implemented
WV0193 # 06 Y:2000 06 2000 BURN A LESS EXPENSIVE GRADE OF FUEL $12,868 $14,400 Not Implemented
WV0193 # 13 Y:2000 13 2000 $3,100 $2,000 Implemented
WV0193 # 11 Y:2000 11 2000 CONTRACT A WOOD PALLET RECYCLING COMPANY $540 $80 Implemented
WV0193 # 08 Y:2000 08 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $161 $500 Not Implemented