Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1998 |
Principal Product | Custom computer snap out forms |
NAICS | n/a |
SIC | 2761 - Manifold Business Forms |
Sales | $5,000,000-$10,000,000 |
# of Employees | 32 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 1,100,000,000 Pieces |
Production Hrs. Annual | 5,976 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $73,090 | 1,630,715 | kWh | $0.04 |
Electricity Demand | $21,414 | 3,966 | kW-months/year | $5.40 |
Natural Gas | $5,218 | 740 | MMBtu | $7.05 |
TOTAL ENERGY COSTS | $880,284 | |||
RECOMMENDED SAVINGS* | $68,240 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $51,320 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $50,460 Cost: $3,000 |
- | - | - | - | - | - | $50,460 | 80,000 | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$50,460 80,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,500 Cost: $6,500 |
$9,300 | 202,227 | $2,200 | 407 | - | - | - | - | - | - |
$9,300 202,227 kWh |
$2,200 407 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $2,990 Cost: $48 |
- | - | - | - | - | - | - | - | $2,990 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$2,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7145 INSTALL SKYLIGHTS |
Savings: $2,240 Cost: $2,960 |
$2,240 | 48,652 | - | - | - | - | - | - | - | - |
$2,240 48,652 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $420 Cost: $200 |
$190 | 4,103 | $230 | 43 | - | - | - | - | - | - |
$190 4,103 kWh |
$230 43 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $140 Cost: $340 |
$120 | 2,638 | $20 | 4 | - | - | - | - | - | - |
$120 2,638 kWh |
$20 4 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $300 Cost: $43 |
- | - | - | - | $300 | 262,800 | - | - | - | - |
- - kWh |
- - kW-months/year |
$300 262,800 Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $190 Cost: $320 |
$150 | 3,224 | $40 | 7 | - | - | - | - | - | - |
$150 3,224 kWh |
$40 7 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $68,240 Cost: $13,411 |
$12,000 | 260,844 | $2,490 | 461 | $300 | 262,800 | $50,460 | 80,000 | $2,990 | - | $12,000 260,844 kWh |
$2,490 461 kW-months/year |
$300 262,800 Tgal |
$50,460 80,000 lb |
$2,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $51,320 Cost: $3,583 |
$310 | 6,741 | $250 | 47 | $300 | 262,800 | $50,460 | 80,000 | - | - | $310 6,741 kWh |
$250 47 kW-months/year |
$300 262,800 Tgal |
$50,460 80,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||