Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1998 |
Principal Product | Custom computer snap out forms |
NAICS | n/a |
SIC | 2761 - Manifold Business Forms |
Sales | $5,000,000-$10,000,000 |
# of Employees | 32 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 1,100,000,000 Pieces |
Production Hrs. Annual | 5,976 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $73,090 | 1,630,715 | kWh | $0.04 |
Electricity Demand | $21,414 | 3,966 | kW-months/year | $5.40 |
Natural Gas | $5,218 | 740 | MMBtu | $7.05 |
TOTAL ENERGY COSTS | $880,284 | |||
RECOMMENDED SAVINGS* | $68,240 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $51,320 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $50,460 Cost: $3,000 |
- | - | - | - | - | - | $50,460 | 80,000 | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$50,460 80,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,500 Cost: $6,500 |
$9,300 | 202,227 | $2,200 | 407 | - | - | - | - | - | - |
$9,300 202,227 kWh |
$2,200 407 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $2,990 Cost: $48 |
- | - | - | - | - | - | - | - | $2,990 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$2,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7145 INSTALL SKYLIGHTS |
Savings: $2,240 Cost: $2,960 |
$2,240 | 48,652 | - | - | - | - | - | - | - | - |
$2,240 48,652 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $420 Cost: $200 |
$190 | 4,103 | $230 | 43 | - | - | - | - | - | - |
$190 4,103 kWh |
$230 43 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $140 Cost: $340 |
$120 | 2,638 | $20 | 4 | - | - | - | - | - | - |
$120 2,638 kWh |
$20 4 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $300 Cost: $43 |
- | - | - | - | $300 | 262,800 | - | - | - | - |
- - kWh |
- - kW-months/year |
$300 262,800 Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $190 Cost: $320 |
$150 | 3,224 | $40 | 7 | - | - | - | - | - | - |
$150 3,224 kWh |
$40 7 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $68,240 Cost: $13,411 |
$12,000 | 260,844 | $2,490 | 461 | $300 | 262,800 | $50,460 | 80,000 | $2,990 | - | $12,000 260,844 kWh |
$2,490 461 kW-months/year |
$300 262,800 Tgal |
$50,460 80,000 lb |
$2,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $51,320 Cost: $3,583 |
$310 | 6,741 | $250 | 47 | $300 | 262,800 | $50,460 | 80,000 | - | - | $310 6,741 kWh |
$250 47 kW-months/year |
$300 262,800 Tgal |
$50,460 80,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Personnel Changes |