Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 1997 |
Principal Product | Fractional Horsepower A/C and D/C Motors |
NAICS | n/a |
SIC | 3621 - Motors And Generators |
Sales | $10,000,000-$50,000,000 |
# of Employees | 325 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 6,000,000 Pieces |
Production Hrs. Annual | 5,640 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,470 | 3,315,651 | kWh | $0.03 |
Electricity Demand | $139,944 | 9,069 | kW-months/year | $15.43 |
Natural Gas | $27,307 | 5,294 | MMBtu | $5.16 |
TOTAL ENERGY COSTS | $265,413 | |||
RECOMMENDED SAVINGS* | $56,024 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $44,717 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,053 Cost: $1,212 |
$2,629 | 93,787 | $3,424 | 19 | - | - | - | - |
$2,629 93,787 kWh |
$3,424 19 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,085 Cost: $186 |
$449 | 16,120 | $636 | 3 | - | - | - | - |
$449 16,120 kWh |
$636 3 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $200 Cost: $229 |
$88 | 3,517 | $112 | 1 | - | - | - | - |
$88 3,517 kWh |
$112 1 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $265 Cost: - |
$122 | 4,396 | $143 | 1 | - | - | - | - |
$122 4,396 kWh |
$143 1 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,152 Cost: $150 |
$530 | 19,050 | $622 | 3 | - | - | - | - |
$530 19,050 kWh |
$622 3 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3136 OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS |
Savings: $89 Cost: - |
$89 | 3,224 | - | 9 | - | - | - | - |
$89 3,224 kWh |
- 9 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $6,309 Cost: $8,400 |
$(-459) | (-8,499) | - | - | $6,768 | 4,230,000 | - | - |
$(-459) (-8,499) kWh |
- - kW-months/year |
$6,768 4,230,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $4,837 Cost: $31,000 |
$(-918) | (-16,999) | - | - | $5,755 | 3,597,000 | - | - |
$(-918) (-16,999) kWh |
- - kW-months/year |
$5,755 3,597,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $31,334 Cost: $2,000 |
- | - | - | - | - | - | $31,334 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$31,334 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $4,700 Cost: $1,000 |
- | - | - | - | - | - | $4,700 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$4,700 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $56,024 Cost: $44,177 |
$2,530 | 114,596 | $4,937 | 36 | $12,523 | 7,827,000 | $36,034 | - | $2,530 114,596 kWh |
$4,937 36 kW-months/year |
$12,523 7,827,000 Tgal |
$36,034 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $44,717 Cost: $41,736 |
$(-398) | 9,672 | $1,258 | 6 | $12,523 | 7,827,000 | $31,334 | - | $(-398) 9,672 kWh |
$1,258 6 kW-months/year |
$12,523 7,827,000 Tgal |
$31,334 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes |