Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 1992
Principal Product NIGHT VISION GOGGLES
NAICS n/a
SIC 3671 - Electron Tubes
Sales $50,000,000-$100,000,000
# of Employees 425
Plant Area (Sq.Ft.) 0
Annual Production 125,000 Pieces
Production Hrs. Annual 6,240
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $982,524 16,513,189 kWh $0.06
TOTAL ENERGY COSTS $982,524
RECOMMENDED SAVINGS* $78,321 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,564
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,606
Cost:
$37,167
$10,063 169,109 $3,543 - $10,063
169,109
kWh
$3,543
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$328
Cost:
$620
$328 5,569 - - $328
5,569
kWh
-
-
$
03: 2.3111 HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE Savings:
$41,247
Cost:
$172,000
$41,247 - - - $41,247
-
kWh
-
-
$
04: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$8,576
Cost:
$20,000
$8,576 288,980 - - $8,576
288,980
kWh
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,806
Cost:
$6,521
$2,806 47,186 - - $2,806
47,186
kWh
-
-
$
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,135
Cost:
$6,047
$1,135 19,050 - - $1,135
19,050
kWh
-
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,014
Cost:
-
$1,014 16,999 - - $1,014
16,999
kWh
-
-
$
08: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$7,367
Cost:
$2,400
$7,367 123,681 - - $7,367
123,681
kWh
-
-
$
09: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,242
Cost:
$190
$2,242 - - - $2,242
-
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$78,321
Cost:
$244,945
$74,778 670,574 $3,543 - $74,778
670,574
kWh
$3,543
-
$
TOTAL IMPLEMENTED Savings:
$14,564
Cost:
$15,158
$14,564 206,916 - - $14,564
206,916
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes