Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2021 |
Principal Product | Potable Water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | <$500,000 |
# of Employees | 37 |
Plant Area (Sq.Ft.) | 2,400,000 |
Annual Production | 14,700,000 Thousand Gallons |
Production Hrs. Annual | 7,656 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,060,409 | 18,049,877 | kWh | $0.06 |
Electricity Demand | $363,972 | 38,616 | kW-months/year | $9.43 |
Electricity Fees | $140,147 | - | $ | - |
TOTAL ENERGY COSTS | $1,564,528 | |||
RECOMMENDED SAVINGS* | $516,487 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $431,439 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $316,547 Cost: $4,413,360 |
$267,990 | 4,231,318 | $48,557 | 5,850 | - | - | - | - |
$267,990 4,231,318 kWh |
$48,557 5,850 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $82,856 Cost: $1,837 |
$47,223 | - | $35,633 | - | - | - | - | - |
$47,223 - kWh |
$35,633 - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $35,467 Cost: $918 |
$14,041 | 237,983 | - | - | $(-8,638) | - | $30,064 | - |
$14,041 237,983 kWh |
- - kW-months/year |
$(-8,638) - $ |
$30,064 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $27,634 Cost: $115 |
- | - | $9,200 | - | - | - | $18,434 | - |
- - kWh |
$9,200 - kW-months/year |
- - $ |
$18,434 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $25,372 Cost: $918 |
$21,262 | 360,380 | $4,110 | 494 | - | - | - | - |
$21,262 360,380 kWh |
$4,110 494 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,834 Cost: $5,555 |
$8,239 | 139,642 | $1,595 | 191 | - | - | - | - |
$8,239 139,642 kWh |
$1,595 191 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $9,147 Cost: $2,290 |
$9,147 | 155,037 | - | - | - | - | - | - |
$9,147 155,037 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,438 Cost: $14,828 |
$6,068 | 102,709 | $1,003 | 120 | - | - | $367 | - |
$6,068 102,709 kWh |
$1,003 120 kW-months/year |
- - $ |
$367 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT |
Savings: $2,192 Cost: $434 |
$1,527 | 25,885 | $665 | 80 | - | - | - | - |
$1,527 25,885 kWh |
$665 80 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $516,487 Cost: $4,440,255 |
$375,497 | 5,252,954 | $100,763 | 6,735 | $(-8,638) | - | $48,865 | - | $375,497 5,252,954 kWh |
$100,763 6,735 kW-months/year |
$(-8,638) - $ |
$48,865 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $431,439 Cost: $4,437,984 |
$326,747 | 5,227,069 | $64,465 | 6,655 | $(-8,638) | - | $48,865 | - | $326,747 5,227,069 kWh |
$64,465 6,655 kW-months/year |
$(-8,638) - $ |
$48,865 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost |