Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 1996 |
Principal Product | Commercial Cleaning Equipment |
NAICS | n/a |
SIC | 3698 - |
Sales | $50,000,000-$100,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 112,000 |
Annual Production | 50,000 Pieces |
Production Hrs. Annual | 4,550 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $61,882 | 1,665,592 | kWh | $0.04 |
Electricity Demand | $64,512 | 5,281 | kW-months/year | $12.22 |
Electricity Fees | $701 | - | $ | - |
Natural Gas | $44,416 | 13,555 | MMBtu | $3.28 |
TOTAL ENERGY COSTS | $184,011 | |||
RECOMMENDED SAVINGS* | $18,936 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,396 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,002 Cost: $3,225 |
$2,708 | 77,960 | $2,294 | 188 | - | - | - | - | - | - |
$2,708 77,960 kWh |
$2,294 188 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,228 Cost: $4,228 |
$2,495 | 71,805 | $1,733 | 142 | - | - | - | - | - | - |
$2,495 71,805 kWh |
$1,733 142 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,652 Cost: $2,000 |
$2,652 | 76,202 | - | - | - | - | - | - | - | - |
$2,652 76,202 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $2,520 Cost: $1,950 |
- | - | - | - | $2,520 | 785 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,520 785 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,744 Cost: $3,591 |
$887 | 25,498 | $857 | 70 | - | - | - | - | - | - |
$887 25,498 kWh |
$857 70 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $631 Cost: $400 |
$631 | 18,171 | - | - | - | - | - | - | - | - |
$631 18,171 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $2,159 Cost: $3,500 |
- | - | - | - | - | - | $(-500) | - | $2,659 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$(-500) - $ |
$2,659 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,936 Cost: $18,894 |
$9,373 | 269,636 | $4,884 | 400 | $2,520 | 785 | $(-500) | - | $2,659 | - | $9,373 269,636 kWh |
$4,884 400 kW-months/year |
$2,520 785 MMBtu |
$(-500) - $ |
$2,659 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,396 Cost: $5,591 |
$3,539 | 101,700 | $857 | 70 | - | - | - | - | - | - | $3,539 101,700 kWh |
$857 70 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Water Consumption |