Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 1999 |
Principal Product | Printed Paper |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $5,000,000-$10,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 5,100,000 Pounds |
Production Hrs. Annual | 6,864 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $60,273 | 1,324,150 | kWh | $0.05 |
Electricity Demand | $47,459 | 3,774 | kW-months/year | $12.58 |
Electricity Fees | $1,279 | - | $ | - |
Natural Gas | $7,482 | 1,558 | MMBtu | $4.80 |
TOTAL ENERGY COSTS | $120,134 | |||
RECOMMENDED SAVINGS* | $36,306 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,375 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $4,723 Cost: $500 |
- | - | - | - | $4,723 | 1,165 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,723 1,165 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $3,506 Cost: $2,000 |
$1,270 | 30,188 | $423 | 41 | $1,813 | 447 | - | - | - | - |
$1,270 30,188 kWh |
$423 41 kW-months/year |
$1,813 447 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $807 Cost: $646 |
$495 | 11,723 | $312 | 25 | - | - | - | - | - | - |
$495 11,723 kWh |
$312 25 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,466 Cost: $2,040 |
$1,068 | 25,498 | $398 | 32 | - | - | - | - | - | - |
$1,068 25,498 kWh |
$398 32 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,416 Cost: $1,614 |
$929 | 22,274 | $487 | 39 | - | - | - | - | - | - |
$929 22,274 kWh |
$487 39 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $867 Cost: $450 |
$571 | 13,775 | $296 | 24 | - | - | - | - | - | - |
$571 13,775 kWh |
$296 24 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $1,453 Cost: $2,410 |
- | - | - | - | - | - | $1,453 | 308,880 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,453 308,880 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.444 INSTALL SYSTEM TO COLLECT SCRAP |
Savings: $22,068 Cost: $8,700 |
- | - | - | - | - | - | - | - | $22,068 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$22,068 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $36,306 Cost: $18,360 |
$4,333 | 103,458 | $1,916 | 161 | $6,536 | 1,612 | $1,453 | 308,880 | $22,068 | - | $4,333 103,458 kWh |
$1,916 161 kW-months/year |
$6,536 1,612 MMBtu |
$1,453 308,880 Tgal |
$22,068 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,375 Cost: $6,024 |
$2,199 | 52,462 | $910 | 80 | $1,813 | 447 | $1,453 | 308,880 | - | - | $2,199 52,462 kWh |
$910 80 kW-months/year |
$1,813 447 MMBtu |
$1,453 308,880 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |