Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2006 |
Principal Product | Plastic |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2754 - Commercial Printing, Gravure |
Sales | $100,000,000-$500,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 450,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,760 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,316,174 | 31,307,563 | kWh | $0.04 |
Electricity Demand | $736,772 | 53,671 | kW-months/year | $13.73 |
Natural Gas | $309,703 | 29,577 | MMBtu | $10.47 |
TOTAL ENERGY COSTS | $2,362,649 | |||
RECOMMENDED SAVINGS* | $390,407 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $224,642 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $180,015 Cost: $152 |
- | - | - | - | $180,015 | 17,193 |
- - kWh |
- - kW-months/year |
$180,015 17,193 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $12,962 Cost: $5,000 |
- | - | - | - | $12,962 | 1,238 |
- - kWh |
- - kW-months/year |
$12,962 1,238 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3113 MAKE ICE DURING OFF PEAK HOURS FOR COOLING |
Savings: $162,249 Cost: $310,000 |
- | - | $162,249 | 11,817 | - | - |
- - kWh |
$162,249 11,817 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $13,938 Cost: - |
- | - | $13,938 | 1,015 | - | - |
- - kWh |
$13,938 1,015 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1222 INSTALL TURBULATORS |
Savings: $2,094 Cost: $1,500 |
- | - | - | - | $2,094 | 208 |
- - kWh |
- - kW-months/year |
$2,094 208 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,516 Cost: - |
$1,649 | 99,332 | $1,867 | 136 | - | - |
$1,649 99,332 kWh |
$1,867 136 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,780 Cost: $800 |
$834 | 50,181 | $946 | 69 | - | - |
$834 50,181 kWh |
$946 69 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,038 Cost: $10,039 |
$4,706 | 283,517 | $5,332 | 388 | - | - |
$4,706 283,517 kWh |
$5,332 388 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,815 Cost: $1,275 |
$1,801 | 108,529 | $2,014 | 147 | - | - |
$1,801 108,529 kWh |
$2,014 147 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $390,407 Cost: $328,766 |
$8,990 | 541,559 | $186,346 | 13,572 | $195,071 | 18,639 | $8,990 541,559 kWh |
$186,346 13,572 kW-months/year |
$195,071 18,639 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $224,642 Cost: $18,766 |
$7,341 | 442,227 | $22,230 | 1,619 | $195,071 | 18,639 | $7,341 442,227 kWh |
$22,230 1,619 kW-months/year |
$195,071 18,639 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |