Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2007 |
Principal Product | paperboard |
NAICS | 322121 - Paper (except Newsprint) Mills |
SIC | 2621 - Paper Mills |
Sales | <$500,000 |
# of Employees | 48 |
Plant Area (Sq.Ft.) | 53,125 |
Annual Production | 1 Units |
Production Hrs. Annual | 8,712 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $802,718 | 19,095,675 | kWh | $0.04 |
Natural Gas | $99,865 | 252,295 | MMBtu | $0.40 |
TOTAL ENERGY COSTS | $902,583 | |||
RECOMMENDED SAVINGS* | $50,568 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Energy | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Energy | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $668 Cost: $450 |
$667 | 15,874 | $1 | 21 | - | - | - | - | - | - |
$667 15,874 kWh |
$1 21 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $460 Cost: $650 |
$459 | 7,323 | $1 | 10 | - | - | - | - | - | - |
$459 7,323 kWh |
$1 10 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,449 Cost: $4,115 |
$5,448 | 129,722 | $1 | 179 | - | - | - | - | - | - |
$5,448 129,722 kWh |
$1 179 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $7,742 Cost: $42,500 |
$7,741 | 184,301 | $1 | 134 | - | - | - | - | - | - |
$7,741 184,301 kWh |
$1 134 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $9,075 Cost: $20,500 |
$9,074 | 216,040 | $1 | 157 | - | - | - | - | - | - |
$9,074 216,040 kWh |
$1 157 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $9,125 Cost: $1,200 |
$9,125 | 714 | - | - | - | - | - | - | - | - |
$9,125 714 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $14,867 Cost: $5,500 |
- | - | - | - | - | - | $14,867 | 2,268,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$14,867 2,268,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.454 MODIFY STARTUP/SHUTDOWN TIMES |
Savings: $2,400 Cost: $7,000 |
- | - | - | - | - | - | - | - | $2,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$2,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $512 Cost: - |
- | - | - | - | - | - | $512 | 55,600 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$512 55,600 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $270 Cost: $150 |
- | - | - | - | $270 | 104 | - | - | - | - |
- - kWh |
- - kW-months/year |
$270 104 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,568 Cost: $82,065 |
$32,514 | 553,974 | $5 | 501 | $270 | 104 | $15,379 | 2,323,600 | $2,400 | - | $32,514 553,974 kWh |
$5 501 kW-months/year |
$270 104 MMBtu |
$15,379 2,323,600 lb |
$2,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Energy | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Energy | Solid Waste (non-haz) | Administrative Changes |