Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2010 |
Principal Product | Track Link and Track Shoe Assemblies |
NAICS | 333120 - Construction Machinery Manufacturing |
SIC | 3531 - Construction Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 290 |
Plant Area (Sq.Ft.) | 210,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 2,080 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $361,999 | 4,117,544 | kWh | $0.09 |
Electricity Demand | $39,709 | 16,980 | kW-months/year | $2.34 |
Electricity Fees | $18,480 | - | $ | - |
Natural Gas | $104,561 | 15,614 | MMBtu | $6.70 |
TOTAL ENERGY COSTS | $524,749 | |||
RECOMMENDED SAVINGS* | $77,136 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7145 INSTALL SKYLIGHTS |
Savings: $9,511 Cost: $30,250 |
$8,149 | 97,594 | $1,362 | 563 | - | - | - | - |
$8,149 97,594 kWh |
$1,362 563 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,119 Cost: $825 |
$2,931 | 35,100 | $188 | 89 | - | - | - | - |
$2,931 35,100 kWh |
$188 89 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $4,319 Cost: $170 |
$3,986 | 47,736 | $333 | 138 | - | - | - | - |
$3,986 47,736 kWh |
$333 138 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,464 Cost: $1,500 |
$3,250 | 38,916 | $214 | 89 | - | - | - | - |
$3,250 38,916 kWh |
$214 89 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,599 Cost: - |
$1,476 | 17,688 | $123 | 51 | - | - | - | - |
$1,476 17,688 kWh |
$123 51 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,109 Cost: $1,220 |
$1,023 | 12,261 | $86 | 35 | - | - | - | - |
$1,023 12,261 kWh |
$86 35 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.132 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST |
Savings: $26,834 Cost: $15,000 |
- | - | - | - | - | - | $26,834 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$26,834 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7145 INSTALL SKYLIGHTS |
Savings: $18,262 Cost: $9,040 |
$16,084 | 185,492 | $2,178 | 1,073 | - | - | - | - |
$16,084 185,492 kWh |
$2,178 1,073 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,679 Cost: $3,600 |
$6,222 | 99,414 | $457 | 294 | - | - | - | - |
$6,222 99,414 kWh |
$457 294 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $2,240 Cost: $3,180 |
- | - | - | - | $2,240 | 320 | - | - |
- - kWh |
- - kW-months/year |
$2,240 320 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,136 Cost: $64,785 |
$43,121 | 534,201 | $4,941 | 2,332 | $2,240 | 320 | $26,834 | - | $43,121 534,201 kWh |
$4,941 2,332 kW-months/year |
$2,240 320 MMBtu |
$26,834 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |