Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2016 |
Principal Product | Planter assembly discs |
NAICS | 332216 - Saw Blade and Handtool Manufacturing |
SIC | 3523 - Farm Machinery And Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 34 |
Plant Area (Sq.Ft.) | 38,145 |
Annual Production | 789,900 Pieces |
Production Hrs. Annual | 3,240 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,552 | 806,567 | kWh | $0.05 |
Electricity Demand | $17,842 | 2,212 | kW-months/year | $8.07 |
Electricity Fees | $768 | - | $ | - |
Natural Gas | $46,241 | 9,034 | MMBtu | $5.12 |
TOTAL ENERGY COSTS | $110,838 | |||
RECOMMENDED SAVINGS* | $195,604 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $190,052 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,155 Cost: $9,455 |
$3,228 | 59,767 | $927 | 115 | - | - | - | - | - | - | - | - |
$3,228 59,767 kWh |
$927 115 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $2,096 Cost: $840 |
$1,628 | 30,139 | $468 | 58 | - | - | - | - | - | - | - | - |
$1,628 30,139 kWh |
$468 58 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $1,149 Cost: $2,000 |
$(-503) | (-9,310) | $(-144) | (-18) | $1,796 | 368 | - | - | - | - | - | - |
$(-503) (-9,310) kWh |
$(-144) (-18) kW-months/year |
$1,796 368 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $738 Cost: $825 |
$488 | 9,027 | $250 | 31 | - | - | - | - | - | - | - | - |
$488 9,027 kWh |
$250 31 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $507 Cost: $600 |
$378 | 6,996 | $129 | 16 | - | - | - | - | - | - | - | - |
$378 6,996 kWh |
$129 16 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $152 Cost: $184 |
$72 | 1,332 | $14 | 2 | - | - | $29 | - | - | - | $37 | - |
$72 1,332 kWh |
$14 2 kW-months/year |
- - MMBtu |
$29 - $ |
- - $ |
$37 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2121 CONVERT TO ELECTROSTATIC POWDER COATING |
Savings: $186,807 Cost: $160,000 |
- | - | - | - | $(-3,609) | (-739) | - | - | $190,416 | - | - | - |
- - kWh |
- - kW-months/year |
$(-3,609) (-739) MMBtu |
- - $ |
$190,416 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $195,604 Cost: $173,904 |
$5,291 | 97,951 | $1,644 | 203 | $(-1,813) | (-371) | $29 | - | $190,416 | - | $37 | - | $5,291 97,951 kWh |
$1,644 203 kW-months/year |
$(-1,813) (-371) MMBtu |
$29 - $ |
$190,416 - $ |
$37 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $190,052 Cost: $162,840 |
$1,125 | 20,829 | $324 | 40 | $(-1,813) | (-371) | - | - | $190,416 | - | - | - | $1,125 20,829 kWh |
$324 40 kW-months/year |
$(-1,813) (-371) MMBtu |
- - $ |
$190,416 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Ancillary Material Cost |