IAC logo
IAC Assessment: CI0035
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0035
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2024
Principal Product Lead Acid Batteries
NAICS 335911 - Storage Battery Manufacturing
SIC 3691 - Storage Batteries
Sales $100,000,000-$500,000,000
# of Employees 175
Plant Area (Sq.Ft.) 160,569
Annual Production 1,600,000 Pieces
Production Hrs. Annual 4,320
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,231,009 17,453,511 kWh $0.13
Electricity Demand $845,492 41,408 kW-months/year $20.42
Electricity Fees $64,506 - $ -
Natural Gas $38,145 2,226 MMBtu $17.14
TOTAL ENERGY COSTS $3,179,152
RECOMMENDED SAVINGS* $400,404 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$155,337
Cost:
$1,217,286
$120,194 940,485 $35,143 1,721 $120,194
940,485
kWh
$35,143
1,721
kW-months/year
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$86,595
Cost:
$200,000
$86,595 677,586 - - $86,595
677,586
kWh
-
-
kW-months/year
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$51,626
Cost:
$1,800
$36,890 288,659 $14,736 722 $36,890
288,659
kWh
$14,736
722
kW-months/year
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$41,839
Cost:
$6,000
$15,763 123,342 $26,076 1,277 $15,763
123,342
kWh
$26,076
1,277
kW-months/year
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$27,879
Cost:
$16,500
$15,060 101,263 $12,819 622 $15,060
101,263
kWh
$12,819
622
kW-months/year
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$14,387
Cost:
$20,213
$9,964 77,967 $4,423 217 $9,964
77,967
kWh
$4,423
217
kW-months/year
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$9,944
Cost:
$9,750
- - $9,944 486 -
-
kWh
$9,944
486
kW-months/year
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,779
Cost:
$4,500
$3,310 25,898 $1,469 72 $3,310
25,898
kWh
$1,469
72
kW-months/year
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,345
Cost:
$2,340
$3,260 25,506 $1,085 53 $3,260
25,506
kWh
$1,085
53
kW-months/year
10: 2.7134 USE PHOTOCELL CONTROLS Savings:
$3,673
Cost:
$1,013
$1,222 9,563 $2,451 120 $1,222
9,563
kWh
$2,451
120
kW-months/year
TOTAL RECOMMENDED Savings:
$400,404
Cost:
$1,479,402
$292,258 2,270,269 $108,146 5,290 $292,258
2,270,269
kWh
$108,146
5,290
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand