Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2024
Principal Product Dairy Products, Yogurt
NAICS 311511 - Fluid Milk Manufacturing
SIC 2026 - Fluid Milk
Sales $5,000,000-$10,000,000
# of Employees 76
Plant Area (Sq.Ft.) 33,000
Annual Production 50,000,000 Pounds
Production Hrs. Annual 7,488
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $251,634 1,830,360 kWh $0.14
Electricity Demand $212,755 13,890 kW-months/year $15.32
Electricity Fees $228,383 - $ -
Natural Gas $134,323 16,014 MMBtu $8.39
Other Gas $45,126 1 MMBtu $45,126.00
TOTAL ENERGY COSTS $954,804
RECOMMENDED SAVINGS* $296,881 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$99,111
Cost:
$675,274
$85,084 618,793 $14,027 916 - - $85,084
618,793
kWh
$14,027
916
kW-months/year
-
-
MMBtu
02: 2.1224 REPLACE BOILER Savings:
$66,255
Cost:
$50,000
$(-23,063) (-167,731) $(-2,059) (-134) $91,377 10,894 $(-23,063)
(-167,731)
kWh
$(-2,059)
(-134)
kW-months/year
$91,377
10,894
MMBtu
03: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$44,001
Cost:
$25,000
$44,001 320,010 - - - - $44,001
320,010
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$33,610
Cost:
$14,000
$28,957 210,594 $4,653 304 - - $28,957
210,594
kWh
$4,653
304
kW-months/year
-
-
MMBtu
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$17,797
Cost:
$90,000
$16,107 117,143 $1,690 110 - - $16,107
117,143
kWh
$1,690
110
kW-months/year
-
-
MMBtu
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$16,424
Cost:
$4,950
$14,484 105,340 $1,940 127 - - $14,484
105,340
kWh
$1,940
127
kW-months/year
-
-
MMBtu
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$8,210
Cost:
$2,325
$7,642 55,580 $568 37 - - $7,642
55,580
kWh
$568
37
kW-months/year
-
-
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,561
Cost:
$4,560
$3,873 28,170 $688 45 - - $3,873
28,170
kWh
$688
45
kW-months/year
-
-
MMBtu
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$4,050
Cost:
$6,000
$3,514 25,558 $536 35 - - $3,514
25,558
kWh
$536
35
kW-months/year
-
-
MMBtu
10: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,862
Cost:
$6,000
- - $2,862 187 - - -
-
kWh
$2,862
187
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$296,881
Cost:
$878,109
$180,599 1,313,457 $24,905 1,626 $91,377 10,894 $180,599
1,313,457
kWh
$24,905
1,626
kW-months/year
$91,377
10,894
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas