Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1993
Principal Product Cement
NAICS n/a
SIC 3241 - Cement, Hydraulic
Sales $10,000,000-$50,000,000
# of Employees 83
Plant Area (Sq.Ft.) 73,000
Annual Production 400,000 Tons
Production Hrs. Annual 8,736
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $3,280,001 75,441,971 kWh $0.04
Natural Gas $3,309,407 1,663,019 MMBtu $1.99
TOTAL ENERGY COSTS $6,589,408
RECOMMENDED SAVINGS* $4,201,770 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,374,840
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.3413 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT Savings:
$2,405,000
Cost:
$6,313,000
$2,405,000 55,318,289 - - - - $2,405,000
55,318,289
kWh
-
-
MMBtu
-
-
$
02: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL Savings:
$1,287,000
Cost:
$325,000
- - - - $1,287,000 - -
-
kWh
-
-
MMBtu
$1,287,000
-
$
03: 2.2428 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC Savings:
$332,600
Cost:
$250,000
- - $332,600 167,130 - - -
-
kWh
$332,600
167,130
MMBtu
-
-
$
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$87,840
Cost:
$1,000
- - $87,840 44,140 - - -
-
kWh
$87,840
44,140
MMBtu
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$81,180
Cost:
$144,120
$81,180 1,867,526 - - - - $81,180
1,867,526
kWh
-
-
MMBtu
-
-
$
06: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$6,180
Cost:
-
$6,180 142,145 - - - - $6,180
142,145
kWh
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,290
Cost:
$1,590
$1,290 29,601 - - - - $1,290
29,601
kWh
-
-
MMBtu
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$430
Cost:
$960
$430 9,965 - - - - $430
9,965
kWh
-
-
MMBtu
-
-
$
09: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$250
Cost:
$150
$190 9,086 $60 30 - - $190
9,086
kWh
$60
30
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$4,201,770
Cost:
$7,035,820
$2,494,270 57,376,612 $420,500 211,300 $1,287,000 - $2,494,270
57,376,612
kWh
$420,500
211,300
MMBtu
$1,287,000
-
$
TOTAL IMPLEMENTED Savings:
$1,374,840
Cost:
$326,000
- - $87,840 44,140 $1,287,000 - -
-
kWh
$87,840
44,140
MMBtu
$1,287,000
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes