Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1996 |
Principal Product | refurbished folding carton machinery |
NAICS | n/a |
SIC | 3554 - Paper Industries Machinery |
Sales | $1,000,000-$5,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 32,000 |
Annual Production | 72,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $19,064 | 598,769 | kWh | $0.03 |
Electricity Demand | $15,784 | 1,570 | kW-months/year | $10.05 |
Electricity Fees | $(-459) | - | $ | - |
Natural Gas | $6,056 | 1,728 | MMBtu | $3.50 |
TOTAL ENERGY COSTS | $45,615 | |||
RECOMMENDED SAVINGS* | $32,059 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $859 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $21,800 Cost: $14,040 |
$3,080 | 96,717 | - | - | - | - | - | - | - | - | $18,720 | - |
$3,080 96,717 kWh |
- - kW-months/year |
- - gal |
- - $ |
- - $ |
$18,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $4,360 Cost: $1,560 |
- | - | - | - | $4,800 | 90 | - | - | $(-440) | - | - | - |
- - kWh |
- - kW-months/year |
$4,800 90 gal |
- - $ |
$(-440) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8125 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER |
Savings: $2,730 Cost: $1,350 |
- | - | - | - | - | - | $1,300 | - | $1,430 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$1,300 - $ |
$1,430 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5146 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID |
Savings: $2,310 Cost: $11,720 |
- | - | - | - | $250 | 1,080 | - | - | $2,060 | - | - | - |
- - kWh |
- - kW-months/year |
$250 1,080 gal |
- - $ |
$2,060 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $554 Cost: $2,458 |
$263 | 8,206 | $291 | 29 | - | - | - | - | - | - | - | - |
$263 8,206 kWh |
$291 29 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $85 Cost: $83 |
$61 | 2,052 | $24 | 2 | - | - | - | - | - | - | - | - |
$61 2,052 kWh |
$24 2 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $220 Cost: $180 |
$140 | 4,396 | $80 | 8 | - | - | - | - | - | - | - | - |
$140 4,396 kWh |
$80 8 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $32,059 Cost: $31,391 |
$3,544 | 111,371 | $395 | 39 | $5,050 | 1,170 | $1,300 | - | $3,050 | - | $18,720 | - | $3,544 111,371 kWh |
$395 39 kW-months/year |
$5,050 1,170 gal |
$1,300 - $ |
$3,050 - $ |
$18,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $859 Cost: $2,721 |
$464 | 14,654 | $395 | 39 | - | - | - | - | - | - | - | - | $464 14,654 kWh |
$395 39 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Primary Product |