Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2001 |
Principal Product | beer |
NAICS | n/a |
SIC | 2082 - Malt Beverages |
Sales | $1,000,000-$5,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 18,500 |
Annual Production | 620,000 Thousand Gallons |
Production Hrs. Annual | 4,160 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $5,105 | 310,724 | kWh | $0.02 |
Electricity Demand | $11,906 | 1,693 | kW-months/year | $7.03 |
Electricity Fees | $507 | - | $ | - |
Natural Gas | $19,879 | 3,420 | MMBtu | $5.81 |
TOTAL ENERGY COSTS | $48,558 | |||
RECOMMENDED SAVINGS* | $8,490 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,060 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | gal | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $1,160 Cost: - |
- | - | $1,160 | 100 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$1,160 100 kW-months/year |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $500 Cost: $1,000 |
- | - | $500 | 108 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$500 108 kW-months/year |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $90 Cost: - |
$50 | 2,800 | $100 | 14 | - | - | - | - | $(-50) | - | $(-10) | - | - | - |
$50 2,800 kWh |
$100 14 kW-months/year |
- - Tgal |
- - gal |
$(-50) - $ |
$(-10) - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $4,810 Cost: $4,730 |
- | - | - | - | $2,870 | 1,400,000 | - | - | - | - | - | - | $1,940 | - |
- - kWh |
- - kW-months/year |
$2,870 1,400,000 Tgal |
- - gal |
- - $ |
- - $ |
$1,940 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5317 SELL / OFFER BY-PRODUCT AS ANIMAL FEED |
Savings: $1,930 Cost: $1,930 |
- | - | - | - | - | - | $1,930 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$1,930 - gal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $8,490 Cost: $7,660 |
$50 | 2,800 | $1,760 | 222 | $2,870 | 1,400,000 | $1,930 | - | $(-50) | - | $(-10) | - | $1,940 | - | $50 2,800 kWh |
$1,760 222 kW-months/year |
$2,870 1,400,000 Tgal |
$1,930 - gal |
$(-50) - $ |
$(-10) - $ |
$1,940 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,060 Cost: $4,730 |
$50 | 2,800 | $1,260 | 114 | $2,870 | 1,400,000 | - | - | $(-50) | - | $(-10) | - | $1,940 | - | $50 2,800 kWh |
$1,260 114 kW-months/year |
$2,870 1,400,000 Tgal |
- - gal |
$(-50) - $ |
$(-10) - $ |
$1,940 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | gal | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Water Disposal | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Water Consumption |