Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2006 |
Principal Product | Roofing asphalt |
NAICS | 324122 - Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 16 |
Plant Area (Sq.Ft.) | 13,100 |
Annual Production | 85,400 Tons |
Production Hrs. Annual | 8,160 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $61,230 | 1,880,960 | kWh | $0.03 |
Electricity Demand | $54,839 | 3,998 | kW-months/year | $13.72 |
Electricity Fees | $212 | - | $ | - |
Natural Gas | $464,300 | 71,415 | MMBtu | $6.50 |
TOTAL ENERGY COSTS | $580,581 | |||
RECOMMENDED SAVINGS* | $511,150 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,700 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.113 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT |
Savings: $479,740 Cost: $28,080 |
- | - | - | - | - | - | $(-2,320) | (-1,189,100) | $(-170,200) | - | - | - | $(-2,000) | - | $654,260 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$(-2,320) (-1,189,100) Tgal |
$(-170,200) - $ |
- - $ |
$(-2,000) - Tgal |
$654,260 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $10,650 Cost: $500 |
- | - | - | - | $10,650 | 1,639 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,650 1,639 MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $9,880 Cost: $3,190 |
- | - | - | - | $9,880 | 1,521 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,880 1,521 MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $3,750 Cost: $12,850 |
- | - | - | - | $2,670 | 411 | $580 | 295,700 | - | - | - | - | $500 | - | - | - |
- - kWh |
- - kW-months/year |
$2,670 411 MMBtu |
$580 295,700 Tgal |
- - $ |
- - $ |
$500 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE |
Savings: $3,310 Cost: $980 |
- | - | - | - | $3,310 | 510 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,310 510 MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $1,460 Cost: $9,360 |
$(-850) | (-26,100) | $(-540) | (-38) | - | - | $1,530 | 785,000 | - | - | - | - | $1,320 | - | - | - |
$(-850) (-26,100) kWh |
$(-540) (-38) kW-months/year |
- - MMBtu |
$1,530 785,000 Tgal |
- - $ |
- - $ |
$1,320 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $50 Cost: $20 |
$30 | 880 | $20 | 1 | - | - | - | - | - | - | - | - | - | - | - | - |
$30 880 kWh |
$20 1 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $900 Cost: $1,610 |
$430 | 13,100 | $270 | 19 | - | - | - | - | - | - | $200 | - | - | - | - | - |
$430 13,100 kWh |
$270 19 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$200 - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $660 Cost: $1,830 |
$360 | 1,100 | $230 | 16 | - | - | - | - | - | - | $70 | - | - | - | - | - |
$360 1,100 kWh |
$230 16 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$70 - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.9113 USE SOLAR HEAT FOR HEAT |
Savings: $470 Cost: $1,400 |
$470 | 14,500 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$470 14,500 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $280 Cost: $500 |
$150 | 4,700 | $100 | 7 | - | - | - | - | $20 | - | $10 | - | - | - | - | - |
$150 4,700 kWh |
$100 7 kW-months/year |
- - MMBtu |
- - Tgal |
$20 - $ |
$10 - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $511,150 Cost: $60,320 |
$590 | 8,180 | $80 | 5 | $26,510 | 4,081 | $(-210) | (-108,400) | $(-170,180) | - | $280 | - | $(-180) | - | $654,260 | - | $590 8,180 kWh |
$80 5 kW-months/year |
$26,510 4,081 MMBtu |
$(-210) (-108,400) Tgal |
$(-170,180) - $ |
$280 - $ |
$(-180) - Tgal |
$654,260 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,700 Cost: $16,680 |
$540 | 6,680 | $350 | 24 | $16,630 | 2,560 | $580 | 295,700 | $20 | - | $80 | - | $500 | - | - | - | $540 6,680 kWh |
$350 24 kW-months/year |
$16,630 2,560 MMBtu |
$580 295,700 Tgal |
$20 - $ |
$80 - $ |
$500 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | Primary Product |