IAC logo
IAC Assessment: CO0627
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0627
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2009
Principal Product Tortillas and frozen foods
NAICS 311830 - Tortilla Manufacturing
SIC 2099 - Food Preparations, Nec
Sales $10,000,000-$50,000,000
# of Employees 225
Plant Area (Sq.Ft.) 196,000
Annual Production 60,400,000 Units
Production Hrs. Annual 2,340
Location (State) NM
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $296,017 6,500,400 kWh $0.05
Electricity Demand $111,489 14,832 kW-months/year $7.52
Electricity Fees $75,845 - $ -
Natural Gas $182,771 32,180 MMBtu $5.68
TOTAL ENERGY COSTS $666,122
RECOMMENDED SAVINGS* $31,030 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,690
Cost:
$1,070
$3,150 59,200 $2,540 195 - - - - - - $3,150
59,200
kWh
$2,540
195
kW-months/year
-
-
$
-
-
$
-
-
$
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,500
Cost:
$460
- - $2,500 192 - - - - - - -
-
kWh
$2,500
192
kW-months/year
-
-
$
-
-
$
-
-
$
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,840
Cost:
$3,240
$800 15,600 $1,040 80 - - - - - - $800
15,600
kWh
$1,040
80
kW-months/year
-
-
$
-
-
$
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,110
Cost:
$5,590
$780 18,300 $330 25 - - - - - - $780
18,300
kWh
$330
25
kW-months/year
-
-
$
-
-
$
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$270
Cost:
$582
$190 4,500 $80 6 - - - - - - $190
4,500
kWh
$80
6
kW-months/year
-
-
$
-
-
$
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,180
Cost:
$29,470
$7,870 160,900 $5,270 404 $90 - - - $(-50) - $7,870
160,900
kWh
$5,270
404
kW-months/year
$90
-
$
-
-
$
$(-50)
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$5,100
Cost:
$45,500
$1,230 21,800 $1,040 80 - - $2,830 - - - $1,230
21,800
kWh
$1,040
80
kW-months/year
-
-
$
$2,830
-
$
-
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,040
Cost:
$2,330
$530 9,900 $410 32 $90 - - - $10 - $530
9,900
kWh
$410
32
kW-months/year
$90
-
$
-
-
$
$10
-
$
09: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$300
Cost:
$650
$260 6,200 $40 3 - - - - - - $260
6,200
kWh
$40
3
kW-months/year
-
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$31,030
Cost:
$88,892
$14,810 296,400 $13,250 1,017 $180 - $2,830 - $(-40) - $14,810
296,400
kWh
$13,250
1,017
kW-months/year
$180
-
$
$2,830
-
$
$(-40)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Administrative Changes Ancillary Material Cost