Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2009 |
Principal Product | Tortillas and frozen foods |
NAICS | 311830 - Tortilla Manufacturing |
SIC | 2099 - Food Preparations, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 225 |
Plant Area (Sq.Ft.) | 196,000 |
Annual Production | 60,400,000 Units |
Production Hrs. Annual | 2,340 |
Location (State) | NM |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $296,017 | 6,500,400 | kWh | $0.05 |
Electricity Demand | $111,489 | 14,832 | kW-months/year | $7.52 |
Electricity Fees | $75,845 | - | $ | - |
Natural Gas | $182,771 | 32,180 | MMBtu | $5.68 |
TOTAL ENERGY COSTS | $666,122 | |||
RECOMMENDED SAVINGS* | $31,030 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,690 Cost: $1,070 |
$3,150 | 59,200 | $2,540 | 195 | - | - | - | - | - | - |
$3,150 59,200 kWh |
$2,540 195 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,500 Cost: $460 |
- | - | $2,500 | 192 | - | - | - | - | - | - |
- - kWh |
$2,500 192 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,840 Cost: $3,240 |
$800 | 15,600 | $1,040 | 80 | - | - | - | - | - | - |
$800 15,600 kWh |
$1,040 80 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,110 Cost: $5,590 |
$780 | 18,300 | $330 | 25 | - | - | - | - | - | - |
$780 18,300 kWh |
$330 25 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $270 Cost: $582 |
$190 | 4,500 | $80 | 6 | - | - | - | - | - | - |
$190 4,500 kWh |
$80 6 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,180 Cost: $29,470 |
$7,870 | 160,900 | $5,270 | 404 | $90 | - | - | - | $(-50) | - |
$7,870 160,900 kWh |
$5,270 404 kW-months/year |
$90 - $ |
- - $ |
$(-50) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $5,100 Cost: $45,500 |
$1,230 | 21,800 | $1,040 | 80 | - | - | $2,830 | - | - | - |
$1,230 21,800 kWh |
$1,040 80 kW-months/year |
- - $ |
$2,830 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,040 Cost: $2,330 |
$530 | 9,900 | $410 | 32 | $90 | - | - | - | $10 | - |
$530 9,900 kWh |
$410 32 kW-months/year |
$90 - $ |
- - $ |
$10 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $300 Cost: $650 |
$260 | 6,200 | $40 | 3 | - | - | - | - | - | - |
$260 6,200 kWh |
$40 3 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,030 Cost: $88,892 |
$14,810 | 296,400 | $13,250 | 1,017 | $180 | - | $2,830 | - | $(-40) | - | $14,810 296,400 kWh |
$13,250 1,017 kW-months/year |
$180 - $ |
$2,830 - $ |
$(-40) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost |