Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2021 |
Principal Product | Plastic conduit |
NAICS | 326122 - Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084 - Plastics Pipe |
Sales | <$500,000 |
# of Employees | 69 |
Plant Area (Sq.Ft.) | 41,500 |
Annual Production | 30,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $325,049 | 9,410,000 | kWh | $0.03 |
Electricity Demand | $365,798 | 17,993 | kW-months/year | $20.33 |
Electricity Fees | $5,869 | - | $ | - |
Natural Gas | $9,522 | 1,170 | MMBtu | $8.14 |
TOTAL ENERGY COSTS | $706,238 | |||
RECOMMENDED SAVINGS* | $183,588 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $87,799 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $48,927 Cost: $491,439 |
$33,012 | 955,734 | $15,915 | 770 | - | - |
$33,012 955,734 kWh |
$15,915 770 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR |
Savings: $38,875 Cost: $547,800 |
$30,126 | 873,210 | $21,499 | 1,041 | $(-12,750) | - |
$30,126 873,210 kWh |
$21,499 1,041 kW-months/year |
$(-12,750) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $15,984 Cost: - |
- | - | $15,984 | 774 | - | - |
- - kWh |
$15,984 774 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $14,264 Cost: $21,000 |
$7,385 | 214,049 | $6,879 | 333 | - | - |
$7,385 214,049 kWh |
$6,879 333 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,303 Cost: $3,500 |
$1,265 | 36,669 | $1,038 | 50 | - | - |
$1,265 36,669 kWh |
$1,038 50 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,794 Cost: - |
$2,239 | 64,896 | $1,555 | 75 | - | - |
$2,239 64,896 kWh |
$1,555 75 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $51,454 Cost: $3,624 |
- | - | $51,454 | 2,532 | - | - |
- - kWh |
$51,454 2,532 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $7,987 Cost: $33,250 |
$9,020 | 262,000 | $(-1,033) | 50 | - | - |
$9,020 262,000 kWh |
$(-1,033) 50 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $183,588 Cost: $1,100,613 |
$83,047 | 2,406,558 | $113,291 | 5,625 | $(-12,750) | - | $83,047 2,406,558 kWh |
$113,291 5,625 kW-months/year |
$(-12,750) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $87,799 Cost: $28,124 |
$10,889 | 315,614 | $76,910 | 3,764 | - | - | $10,889 315,614 kWh |
$76,910 3,764 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |