IAC Center | Colorado State University |
---|---|
Assessment Year | 2021 |
Principal Product | Plastic conduit |
NAICS | 326122 - Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084 - Plastics Pipe |
Sales | <$500,000 |
# of Employees | 69 |
Plant Area (Sq.Ft.) | 41,500 |
Annual Production | 30,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $325,049 | 9,410,000 | kWh | $0.03 |
Electricity Demand | $365,798 | 17,993 | kW-months/year | $20.33 |
Electricity Fees | $5,869 | - | $ | - |
Natural Gas | $9,522 | 1,170 | MMBtu | $8.14 |
TOTAL ENERGY COSTS | $706,238 | |||
RECOMMENDED SAVINGS* | $183,588 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $87,799 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $48,927 Cost: $491,439 |
$33,012 | 955,734 | $15,915 | 770 | - | - |
$33,012 955,734 kWh |
$15,915 770 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR |
Savings: $38,875 Cost: $547,800 |
$30,126 | 873,210 | $21,499 | 1,041 | $(-12,750) | - |
$30,126 873,210 kWh |
$21,499 1,041 kW-months/year |
$(-12,750) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $15,984 Cost: - |
- | - | $15,984 | 774 | - | - |
- - kWh |
$15,984 774 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $14,264 Cost: $21,000 |
$7,385 | 214,049 | $6,879 | 333 | - | - |
$7,385 214,049 kWh |
$6,879 333 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,303 Cost: $3,500 |
$1,265 | 36,669 | $1,038 | 50 | - | - |
$1,265 36,669 kWh |
$1,038 50 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,794 Cost: - |
$2,239 | 64,896 | $1,555 | 75 | - | - |
$2,239 64,896 kWh |
$1,555 75 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $51,454 Cost: $3,624 |
- | - | $51,454 | 2,532 | - | - |
- - kWh |
$51,454 2,532 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $7,987 Cost: $33,250 |
$9,020 | 262,000 | $(-1,033) | 50 | - | - |
$9,020 262,000 kWh |
$(-1,033) 50 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $183,588 Cost: $1,100,613 |
$83,047 | 2,406,558 | $113,291 | 5,625 | $(-12,750) | - | $83,047 2,406,558 kWh |
$113,291 5,625 kW-months/year |
$(-12,750) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $87,799 Cost: $28,124 |
$10,889 | 315,614 | $76,910 | 3,764 | - | - | $10,889 315,614 kWh |
$76,910 3,764 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |