Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Case Western Reserve University
Assessment Year 2021
Principal Product Commercial and Military Aircraft Power Generation
NAICS 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $1,000,000-$5,000,000
# of Employees 130
Plant Area (Sq.Ft.) 44,000
Annual Production 13,000 Units
Production Hrs. Annual 3,000
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $67,614 1,432,500 kWh $0.05
Electricity Demand $56,540 5,040 kW-months/year $11.22
Electricity Fees $20,863 - $ -
TOTAL ENERGY COSTS $145,018
RECOMMENDED SAVINGS* $1,085,605 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,085,605
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Primary Product Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Primary Product
$ kWh $ kW-months/year $ $ $ $ $ $
01: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$30,000
Cost:
$70,084
- - - - - - - - $30,000 - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
$30,000
-
$
02: 4.651 INSTALL BACK-UP EQUIPMENT Savings:
$32,054
Cost:
$93,000
- - - - $32,054 - - - - - -
-
kWh
-
-
kW-months/year
$32,054
-
$
-
-
$
-
-
$
03: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL Savings:
$18,089
Cost:
$25,885
$18,089 383,250 - - - - - - - - $18,089
383,250
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
04: 4.454 MODIFY STARTUP/SHUTDOWN TIMES Savings:
$2,380
Cost:
$100,000
$2,380 50,430 - - - - - - - - $2,380
50,430
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
05: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$1,965
Cost:
$510
$191 4,053 $1,774 158 - - - - - - $191
4,053
kWh
$1,774
158
kW-months/year
-
-
$
-
-
$
-
-
$
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$899
Cost:
-
$899 19,049 - - - - - - - - $899
19,049
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$1,000,000
Cost:
$122,000
- - - - - - $1,000,000 - - - -
-
kWh
-
-
kW-months/year
-
-
$
$1,000,000
-
$
-
-
$
08: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$217
Cost:
$86
$217 4,596 - - - - - - - - $217
4,596
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$1,085,605
Cost:
$411,565
$21,777 461,377 $1,774 158 $32,054 - $1,000,000 - $30,000 - $21,777
461,377
kWh
$1,774
158
kW-months/year
$32,054
-
$
$1,000,000
-
$
$30,000
-
$
TOTAL IMPLEMENTED Savings:
$1,085,605
Cost:
$411,565
$21,777 461,377 $1,774 158 $32,054 - $1,000,000 - $30,000 - $21,777
461,377
kWh
$1,774
158
kW-months/year
$32,054
-
$
$1,000,000
-
$
$30,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $ $ $
Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Primary Product Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Primary Product