Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Case Western Reserve University |
---|---|
Assessment Year | 2022 |
Principal Product | Actuators for the oil, natural gas, mining and chemical industries |
NAICS | 333995 - Fluid Power Cylinder and Actuator Manufacturing |
SIC | 3593 - Fluid Power Cylinders & Actuators |
Sales | $50,000,000-$100,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 540,000 |
Annual Production | 1,000,000 Units |
Production Hrs. Annual | 4,380 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $64,912 | 1,138,800 | kWh | $0.06 |
Electricity Demand | $46,226 | 4,918 | kW-months/year | $9.40 |
Electricity Fees | $111,137 | - | $ | - |
Natural Gas | $41,597 | 9,306 | MMBtu | $4.47 |
TOTAL ENERGY COSTS | $263,871 | |||
RECOMMENDED SAVINGS* | $63,508 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $17,675 Cost: $20,960 |
$(-527) | 9,250 | - | - | - | - | $18,202 | 4,075 | - | - |
$(-527) 9,250 kWh |
- - kW-months/year |
- - $ |
$18,202 4,075 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $12,461 Cost: $15,547 |
- | - | - | - | - | - | $12,461 | 2,790 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$12,461 2,790 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $361 Cost: - |
$(-146) | 2,555 | - | - | - | - | $305 | 68 | $202 | - |
$(-146) 2,555 kWh |
- - kW-months/year |
- - $ |
$305 68 MMBtu |
$202 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $19,047 Cost: $54,963 |
$6,573 | 115,319 | $12,473 | 1,327 | - | - | - | - | - | - |
$6,573 115,319 kWh |
$12,473 1,327 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8227 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION |
Savings: $10,872 Cost: $33,000 |
- | - | - | - | - | - | - | - | $10,872 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$10,872 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $921 Cost: - |
- | - | - | - | $921 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$921 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9113 USE SOLAR HEAT FOR HEAT |
Savings: $2,171 Cost: $13,500 |
$2,171 | 38,086 | - | - | - | - | - | - | - | - |
$2,171 38,086 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,508 Cost: $137,970 |
$8,071 | 165,210 | $12,473 | 1,327 | $921 | - | $30,968 | 6,933 | $11,074 | - | $8,071 165,210 kWh |
$12,473 1,327 kW-months/year |
$921 - $ |
$30,968 6,933 MMBtu |
$11,074 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost |