Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1983
Principal Product CARPET
NAICS n/a
SIC 2273 - Carpets And Rugs
Sales $50,000,000-$100,000,000
# of Employees 300
Plant Area (Sq.Ft.) 0
Annual Production 28,800 Thousand Feet
Production Hrs. Annual 6,000
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $243,042 4,116,940 kWh $0.06
Natural Gas $885,248 192,912 MMBtu $4.59
TOTAL ENERGY COSTS $1,128,290
RECOMMENDED SAVINGS* $240,455 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $240,455
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$15,132
Cost:
$500
- - $15,132 3,420 -
-
kWh
$15,132
3,420
MMBtu
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$28,745
Cost:
$50,000
- - $28,745 6,488 -
-
kWh
$28,745
6,488
MMBtu
03: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$22,837
Cost:
$10,000
- - $22,837 5,155 -
-
kWh
$22,837
5,155
MMBtu
04: 2.5191 MODIFY DYE BECK Savings:
$58,597
Cost:
$101,000
- - $58,597 13,227 -
-
kWh
$58,597
13,227
MMBtu
05: 2.5191 MODIFY DYE BECK Savings:
$38,740
Cost:
$51,000
- - $38,740 8,745 -
-
kWh
$38,740
8,745
MMBtu
06: 2.5192 MODIFY TEXTILE DRYERS Savings:
$33,809
Cost:
$35,000
- - $33,809 7,446 -
-
kWh
$33,809
7,446
MMBtu
07: 2.1111 CONTROL PRESSURE ON STEAMER OPERATIONS Savings:
$7,770
Cost:
$3,500
- - $7,770 1,754 -
-
kWh
$7,770
1,754
MMBtu
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$4,897
Cost:
$400
- - $4,897 1,104 -
-
kWh
$4,897
1,104
MMBtu
09: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$2,028
Cost:
$4,000
$1,059 20,223 $969 214 $1,059
20,223
kWh
$969
214
MMBtu
10: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$27,900
Cost:
$50,000
$27,900 - - - $27,900
-
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$240,455
Cost:
$305,400
$28,959 20,223 $211,496 47,553 $28,959
20,223
kWh
$211,496
47,553
MMBtu
TOTAL IMPLEMENTED Savings:
$240,455
Cost:
$305,400
$28,959 20,223 $211,496 47,553 $28,959
20,223
kWh
$211,496
47,553
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas