Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1985 |
Principal Product | MENS'& BOYS' UNDERWEAR |
NAICS | n/a |
SIC | 2254 - Knit Underwear Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 669 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 12,400,000 Pieces |
Production Hrs. Annual | 1,960 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $249,525 | 4,271,981 | kWh | $0.06 |
Natural Gas | $62,587 | 12,923 | MMBtu | $4.84 |
Fuel Oil #6 | $14,162 | 2,584 | MMBtu | $5.48 |
TOTAL ENERGY COSTS | $326,274 | |||
RECOMMENDED SAVINGS* | $61,334 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $61,334 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Fuel Oil #6 | Electricity Usage | Natural Gas | Fuel Oil #6 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $18,590 Cost: $250 |
$18,590 | 317,995 | - | - | - | - |
$18,590 317,995 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,568 Cost: $560 |
$6,568 | 112,544 | - | - | - | - |
$6,568 112,544 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1224 REPLACE BOILER |
Savings: $11,945 Cost: $32,000 |
- | - | $9,769 | 2,078 | $2,176 | 396 |
- - kWh |
$9,769 2,078 MMBtu |
$2,176 396 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $550 Cost: $600 |
$550 | 9,379 | - | - | - | - |
$550 9,379 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $8,866 Cost: - |
- | - | $7,252 | 1,543 | $1,614 | 294 |
- - kWh |
$7,252 1,543 MMBtu |
$1,614 294 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,882 Cost: $2,280 |
- | - | $1,542 | 328 | $340 | 62 |
- - kWh |
$1,542 328 MMBtu |
$340 62 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $993 Cost: $894 |
$993 | 16,999 | - | - | - | - |
$993 16,999 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $11,940 Cost: $15,000 |
$11,940 | - | - | - | - | - |
$11,940 - kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $61,334 Cost: $51,584 |
$38,641 | 456,917 | $18,563 | 3,949 | $4,130 | 752 | $38,641 456,917 kWh |
$18,563 3,949 MMBtu |
$4,130 752 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $61,334 Cost: $51,584 |
$38,641 | 456,917 | $18,563 | 3,949 | $4,130 | 752 | $38,641 456,917 kWh |
$18,563 3,949 MMBtu |
$4,130 752 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||