Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1986
Principal Product AUOTOMOTIVE COMPONENTS
NAICS n/a
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $10,000,000-$50,000,000
# of Employees 490
Plant Area (Sq.Ft.) 0
Annual Production 1,380,000 Pieces
Production Hrs. Annual 6,000
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $826,534 18,609,027 kWh $0.04
Natural Gas $527,865 99,217 MMBtu $5.32
TOTAL ENERGY COSTS $1,354,399
RECOMMENDED SAVINGS* $117,146 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $117,146
#|Description Savings
Cost
Status Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes
$ kWh $ MMBtu $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,616
Cost:
$1,866
$1,616 36,635 - - - - - - $1,616
36,635
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,278
Cost:
$218
$5,278 118,699 - - - - - - $5,278
118,699
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,183
Cost:
$300
- - - - $5,183 1,941 $(-1,000) - -
-
kWh
-
-
MMBtu
$5,183
1,941
MMBtu
$(-1,000)
-
$
04: 2.1333 CONVERT COMBUSTION EQUIPMENT TO BURN OIL Savings:
$56,269
Cost:
-
- - $159,375 37,500 $(-103,106) (-38,617) - - -
-
kWh
$159,375
37,500
MMBtu
$(-103,106)
(-38,617)
MMBtu
-
-
$
05: 2.2212 USE MINIMUM SAFE OVEN VENTILATION Savings:
$46,250
Cost:
$10,000
- - $46,250 10,886 - - - - -
-
kWh
$46,250
10,886
MMBtu
-
-
MMBtu
-
-
$
06: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR Savings:
$3,550
Cost:
$8,000
- - - - $3,550 1,330 - - -
-
kWh
-
-
MMBtu
$3,550
1,330
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$117,146
Cost:
$20,384
$6,894 155,334 $205,625 48,386 $(-94,373) (-35,346) $(-1,000) - $6,894
155,334
kWh
$205,625
48,386
MMBtu
$(-94,373)
(-35,346)
MMBtu
$(-1,000)
-
$
TOTAL IMPLEMENTED Savings:
$117,146
Cost:
$20,384
$6,894 155,334 $205,625 48,386 $(-94,373) (-35,346) $(-1,000) - $6,894
155,334
kWh
$205,625
48,386
MMBtu
$(-94,373)
(-35,346)
MMBtu
$(-1,000)
-
$
Savings
Cost
$ kWh $ MMBtu $ MMBtu $ $
Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes