Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Business and Insurance Forms |
NAICS | n/a |
SIC | 2761 - Manifold Business Forms |
Sales | $10,000,000-$50,000,000 |
# of Employees | 115 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 72,000,000 Pieces |
Production Hrs. Annual | 4,165 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $31,366 | 494,725 | kWh | $0.06 |
Electricity Demand | $52,405 | 2,273 | kW-months/year | $23.06 |
Electricity Fees | $6,401 | - | $ | - |
Natural Gas | $2,565 | 244 | MMBtu | $10.51 |
Fuel Oil #6 | $35,024 | 6,884 | MMBtu | $5.09 |
TOTAL ENERGY COSTS | $127,761 | |||
RECOMMENDED SAVINGS* | $361,231 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,309 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #6 | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Fuel Oil #6 | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,200 Cost: $11,954 |
$4,496 | 70,926 | $4,704 | 204 | - | - | - | - |
$4,496 70,926 kWh |
$4,704 204 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $89 Cost: $75 |
$89 | 1,465 | - | - | - | - | - | - |
$89 1,465 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $388 Cost: $1,000 |
$388 | 6,155 | - | - | - | - | - | - |
$388 6,155 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $9,585 Cost: $1,502 |
$9,585 | 267,292 | - | - | - | - | - | - |
$9,585 267,292 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $660 Cost: $628 |
- | - | - | - | $660 | 130 | - | - |
- - kWh |
- - kW-months/year |
$660 130 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $340,000 Cost: - |
- | - | - | - | - | - | $340,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$340,000 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.511 EXPAND OPERATIONS INTO UNUSED SPACE |
Savings: $1,309 Cost: $20,000 |
$630 | 9,965 | $679 | 30 | - | - | - | - |
$630 9,965 kWh |
$679 30 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $361,231 Cost: $35,159 |
$15,188 | 355,803 | $5,383 | 234 | $660 | 130 | $340,000 | - | $15,188 355,803 kWh |
$5,383 234 kW-months/year |
$660 130 MMBtu |
$340,000 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,309 Cost: $20,000 |
$630 | 9,965 | $679 | 30 | - | - | - | - | $630 9,965 kWh |
$679 30 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #6 | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Fuel Oil #6 | Solid Waste (non-haz) |