Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Hofstra Univ.
Assessment Year 1996
Principal Product Heat Treaters
NAICS n/a
SIC 3398 - Metal Heat Treating
Sales $1,000,000-$5,000,000
# of Employees 24
Plant Area (Sq.Ft.) 20,000
Annual Production 3,900,000 Pounds
Production Hrs. Annual 6,240
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $67,757 1,003,224 kWh $0.07
Electricity Demand $24,973 2,786 kW-months/year $8.96
Natural Gas $138,016 29,051 MMBtu $4.75
TOTAL ENERGY COSTS $230,746
RECOMMENDED SAVINGS* $9,417 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,587
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz) Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz)
$ kWh $ kW-months/year $ MMBtu $ gal
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$598
Cost:
$1,530
$408 5,569 $190 24 - - - - $408
5,569
kWh
$190
24
kW-months/year
-
-
MMBtu
-
-
gal
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$300
Cost:
$343
$300 4,103 - - - - - - $300
4,103
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$399
Cost:
$400
$322 4,396 $77 9 - - - - $322
4,396
kWh
$77
9
kW-months/year
-
-
MMBtu
-
-
gal
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,870
Cost:
$1,129
- - - - $4,870 1,025 - - -
-
kWh
-
-
kW-months/year
$4,870
1,025
MMBtu
-
-
gal
05: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$2,290
Cost:
$3,000
- - - - $2,290 482 - - -
-
kWh
-
-
kW-months/year
$2,290
482
MMBtu
-
-
gal
06: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$960
Cost:
$1,000
- - - - - - $960 120 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$960
120
gal
TOTAL RECOMMENDED Savings:
$9,417
Cost:
$7,402
$1,030 14,068 $267 33 $7,160 1,507 $960 120 $1,030
14,068
kWh
$267
33
kW-months/year
$7,160
1,507
MMBtu
$960
120
gal
TOTAL IMPLEMENTED Savings:
$3,587
Cost:
$5,273
$1,030 14,068 $267 33 $2,290 482 - - $1,030
14,068
kWh
$267
33
kW-months/year
$2,290
482
MMBtu
-
-
gal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ gal
Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz) Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz)