Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | pretzels |
NAICS | n/a |
SIC | 2052 - Cookies And Crackers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 60,000,000 Pounds |
Production Hrs. Annual | 5,880 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $377,158 | 7,450,469 | kWh | $0.05 |
Electricity Demand | $84,930 | 13,188 | kW-months/year | $6.44 |
Electricity Fees | $(-26,939) | - | $ | - |
Natural Gas | $1,152,353 | 272,412 | MMBtu | $4.23 |
TOTAL ENERGY COSTS | $1,617,502 | |||
RECOMMENDED SAVINGS* | $157,217 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $84,819 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,566 Cost: $25,636 |
$6,248 | 122,802 | $2,318 | 360 | - | - | - | - | - | - |
$6,248 122,802 kWh |
$2,318 360 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $6,519 Cost: $9,190 |
$6,519 | 128,664 | - | - | - | - | - | - | - | - |
$6,519 128,664 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $12,311 Cost: $1,200 |
- | - | - | - | $12,311 | 830 | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,311 830 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $36,268 Cost: $18,500 |
- | - | - | - | $36,268 | 8,574 | - | - | - | - |
- - kWh |
- - kW-months/year |
$36,268 8,574 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $24,394 Cost: $13,600 |
$36,724 | 729,484 | - | - | $(-12,330) | (-2,914) | - | - | - | - |
$36,724 729,484 kWh |
- - kW-months/year |
$(-12,330) (-2,914) MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $26,460 Cost: $103,176 |
- | - | - | - | - | - | - | - | $26,460 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$26,460 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $26,460 Cost: $30,270 |
- | - | - | - | - | - | - | - | $26,460 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$26,460 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $15,135 Cost: $200 |
- | - | - | - | - | - | $15,135 | 336,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$15,135 336,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.7141 IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM |
Savings: $1,104 Cost: $535 |
- | - | - | - | - | - | - | - | $1,104 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$1,104 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $157,217 Cost: $202,307 |
$49,491 | 980,950 | $2,318 | 360 | $36,249 | 6,490 | $15,135 | 336,000 | $54,024 | - | $49,491 980,950 kWh |
$2,318 360 kW-months/year |
$36,249 6,490 MMBtu |
$15,135 336,000 lb |
$54,024 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $84,819 Cost: $127,366 |
$43,243 | 858,148 | - | - | $(-19) | (-2,084) | $15,135 | 336,000 | $26,460 | - | $43,243 858,148 kWh |
- - kW-months/year |
$(-19) (-2,084) MMBtu |
$15,135 336,000 lb |
$26,460 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes |